Introduction
Ultrapure Water System delivers Class I ultrapure water with a conductivity of 0.055 µS/cm at 25°C. It ensures very low levels of total organic carbon, endotoxins, particulates, and bacteria. The compact design supports dual-wave UV and ultrafiltration modules based on feed water quality. It performs well across a wide range of pressures and temperatures. Our Ultrapure Water System is ideal for clinical, pharmaceutical, and electronics applications requiring high-purity water.
This water purification system is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Our Ultrapure Water System is also ideal for reagent preparation, glassware rinsing, and conducting sensitive electrochemical or spectrophotometric analyses, ensuring high accuracy and reliability in sensitive laboratory procedures.
Specifications
| Source | RO, Distilled, DI water |
| Water Temperature | 5℃ to 40℃ |
| Water Pressure | 0.1 to 0.8 MPa |
| Class I Resistivity (25℃) | 18.2 MΩ.cm |
| Class I Conductivity (25℃) | 0.055 us/cm |
| Class I Water Total Organic Level | 1 to 5 ppb |
| Class I Flow Rate | 1.5 to 2.0 L/min |
| Class I Particulate Matter (≥0.02um) | ≤1 pc/ml |
| Electrical Voltage | 110 V/220 V±10% |
| Electrical Frequency | 50 Hz/60 Hz |
| External Dimension (Main Units) | 315 × 525 × 570 mm |
| External Dimension (Water Tank) | 380 × 380 × 595 mm |
| Net Weight (Main Units) | 32 Kg |
| Net Weight (Water Tank) | 4.5 Kg |
Features
Water-Electricity Separation
-Based Tracking
Continuous Purity Assurance
Complete System Sanitization
Leak Detection System
FAQs
1. Is the Ultrapure Water System suitable for sensitive or critical applications?
Absolutely. The Ultrapure Water System delivers water that meets stringent purity standards required for sensitive analytical and biological applications. Its ability to remove trace contaminants makes it ideal for techniques like , spectrophotometry, and cell culture. The stable water quality ensures reproducibility in results, which is critical in research and diagnostics. Additionally, the system’s internal construction materials are selected to minimize leaching or contamination. This makes it a trusted solution for laboratories that demand the highest level of reliability and performance.
2. How does the Ultrapure Water System ensure consistent water purity over time?
The Ultrapure Water System utilizes intelligent purification control with continuous conductivity and monitoring to ensure consistent water quality. It automatically tracks filter usage, alerts the user before consumables reach end-of-life, and includes an auto-flush function that prevents membrane fouling. The filtration stages are designed to remove a wide range of impurities including organics, inorganics, bacteria, and particles. Advanced algorithms within the system ensure that any deviation in performance is promptly corrected or reported. This proactive management approach greatly extends the lifespan of purification components and maintains purity levels over prolonged usage.
3. Can the Ultrapure Water System operate in areas with low water pressure or quality?
Yes, the Ultrapure Water System includes a built-in booster pump and robust pretreatment modules that allow it to function effectively even with variable feed water quality or pressure. The pump maintains stable flow rates, ensuring consistent purification performance regardless of external conditions. The pretreatment stage removes chlorine, particulates, and hardness to protect downstream components and maintain system longevity. This makes the unit especially suitable for installation in locations with uncertain water infrastructure. However, for highly contaminated or non-potable sources, additional pretreatment may be recommended.
4. Does the Ultrapure Water System Series support data logging or traceability?
Yes, the Ultrapure Water System comes equipped with digital logging functions that record key operational parameters such as conductivity, levels, filter usage, and error history. This data can be viewed directly on the touch screen display or exported through or network connections, depending on the model. This feature is especially valuable in regulated environments where traceability and audit readiness are essential. The logs also support troubleshooting and service diagnostics, making system upkeep more efficient. By providing full operational transparency, the system aligns with Good Laboratory Practice () requirements.
5. How is microbial contamination prevented in the Ultrapure Water System ?
The Ultrapure Water System uses a combination of UV sterilization, terminal filters (such as 0.2 ?m filters), and a sealed loop design to minimize the risk of microbial contamination. The UV lamp continuously sterilizes water to prevent biofilm formation and bacterial growth. Additionally, the system's smooth internal flow paths and regular auto-rinsing functions further inhibit microbial buildup. Some models also offer endotoxin filters or ultrafiltration modules for applications with stringent biological safety requirements. Together, these features ensure the water remains microbiologically safe for sensitive uses like molecular biology or cell culture.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.