Introduction

Heating features a multipurpose thermostatic shaker with a temperature setting range of 0 °C to 100 °C. Its brushless DC motor ensures quiet operation, long life, and maintenance-free performance. The Shaker incorporates a intelligent temperature control system that ensures accuracy and reduces waiting time. It supports multi-program and multi-point operations. Our Heating Lid Thermo Shaker is widely used for sample incubation, enzymatic reactions, nucleic acid hybridization, protein denaturation, and cell lysis processes.

This thermo-shakers is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Our Heating Lid Thermo Shaker is widely used in applications such as sample incubation, enzymatic reactions, nucleic acid hybridization, protein denaturation, and cell lysis processes. Its ability to maintain uniform temperature and deliver rapid mixing makes it ideal for molecular biology, biochemistry, clinical diagnostics, and pharmaceutical workflows.

Specifications

Temperature Setting Range 0 °C to 100 °C
Temperature Control Range RT +5 ℃ to 100 ℃
Shaking Speed Range 200 to 3000 rpm
Temperature Accuracy Up to ±0.2 ℃ at 37 ℃
Temperature Uniformity Up to ±0.2 ℃ at 37 ℃
Orbit 2 mm
Timing Range 1 min to 99 h 59 min/ ∞
Heating Time Up to 15 min (from 25 ℃ to 100 ℃)
Heating Lid Temp. Setting Range /0 to +15 ℃
Heating Lid Temp. Control Mode Automatic / Manual
Multi-Point Running Yes (max. 5 points)
Multi Cycle Yes (max 99 times)
Auto Constant Temperature att End of Run Yes
Auto Preheating Yes
Auto Running Yes
Auto Resume To Run Yes
Block Quantity 2
Display Accuracy 0.1 ℃
Power Requirement AC 220V or AC 110V, 50/60Hz, 450W
Fuse 250V 3A Φ5 × 20
Dimensions 296 × 212 × 164 mm
Net Weight 6.9 Kg

Features

display

Large capacity

Automatic adjustment of temperature

Compact design

FAQs

1. Why the brushless DC motor used in the Heating Lid Thermo Shaker ?

The Heating Lid Thermo Shaker is equipped with a brushless DC motor to ensure smooth, quiet, and maintenance-free operation. Unlike traditional motors, brushless DC motors have no friction-causing brushes, which significantly reduces wear and enhances durability. This leads to longer operational life, high-speed stability, and better energy efficiency. It's ideal for continuous lab use where reliability and low noise are essential. Additionally, it supports precise and consistent shaking without vibration.

2. How does the heating lid improve the efficiency of shaking in Heating Lid Thermo Shaker ?

The heating lid in the Heating Lid Thermo Shaker maintains uniform temperature from the top of the sample tubes, minimizing condensation during shaking. This ensures that the sample volumes remain stable and do not evaporate, especially in temperature-sensitive reactions. It also prevents cross-contamination by sealing the sample environment. The lid complements the base heating, making the thermal profile more efficient and enhancing reproducibility in experiments. This design significantly improves overall assay quality and consistency.

3. How long can we continuously run the Heating Lid Thermo Shaker ?

Heating Lid Thermo Shaker supports extended operational times with a timer range of 1 min to 99 hours and 59 minutes, offering great flexibility for both short and long incubation processes. It is designed to handle long-term experiments without overheating, thanks to its brushless motor and intelligent control system. The built-in safety features such as auto-stop and overheating protection also ensure safe continuous use. You can confidently run overnight or multi-step procedures without interruptions. This makes it perfect for demanding lab protocols.

4. What are the automatic features included in the Heating Lid Thermo Shaker ?

Heating Lid Thermo Shaker is packed with smart automation features to simplify laboratory workflows. It includes automatic preheating, auto resume after power failure, and auto stop at the end of the cycle. Users can also benefit from multi-point and multi-cycle running modes for complex experiments. These features reduce manual supervision and enhance precision and reproducibility. The system is engineered for intelligent, hands-free operation with minimal user intervention.

5. What makes the Heating Lid Thermo Shaker ideal for laboratory use?

The Heating Lid Thermo Shaker is specifically built for high-performance lab environments, offering a wide temperature range (0°C–100°C), high-speed shaking (up to 2000 rpm), and uniform heating. Its display, real-time monitoring, and intuitive interface make it user-friendly for both novice and experienced lab professionals. Compatibility with multiple tube types and optional blocks increases its versatility. The heating lid, temperature calibration, and anti-evaporation design further ensure reliable results. All these features make it an essential, all-in-one tool for modern bioscience and chemical labs.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.