Introduction
Portable Multiparameter Water Quality Analyzer has a total nitrogen measuring range of 0.00 to 100.0mg/L. Along with total nitrogen, it also measures total phosphorus, ammonia nitrogen and of water samples. It features separate device and digester which does not affect the measurement accuracy. Utilizes catalytic digestion for automated measurement of 4 samples per run. Perfect for outdoor and on-site use in drinking water analysis, environmental monitoring and wastewater treatment.
This water testing equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Our Portable Multiparameter Water Quality Analyzer features an easy to carry high-strength suitcase, making it ideal for analysis of drinking water, wastewater, surface water, effluents and environmental monitoring samples.
Specifications
| Measuring Range | 5.00 to 2000mg/L |
| Indication Error | Less than or equal to 5% |
| Digestion Temperature | 165°C |
| Digestion Period | 15min |
| Ammonia Nitrogen Measuring Range | 0.02 to 25.00mg/L |
| Ammonia Nitrogen Indication Error | Less than or equal to 3% |
| Total Phosphorus Measuring Range | 0.00 to 10.00mg/L |
| Total Phosphorus Indication Error | Less than or equal to 5% |
| Total Phosphorus Digestion Temperature | 120°C |
| Total Phosphorus Digestion Period | 30min |
| Total Nitrogen Measuring Range | 0.05 to 100.00mg/L |
| Total Nitrogen Indication Error | Less than or equal to 5% |
| Total Nitrogen Digestion Temperature | 125°C |
| Total Nitrogen Digestion Period | 30min |
| Total Nitrogen Repeatability | Less than equal to 2% |
| Optical stability | Absorbance drift less than or equal to 0.002A/20min |
| Batch Processing | 4 samples per run or 16 water samples |
| Power Supply | AC 220(165V to 240V) |
| Power Consumption | 10W |
| Digester Power Consumption | 60W |
| Dimension | 230mm × 88mm × 52mm |
| Digester Dimension | 105mm × 160mm × 97mm |
| Weight | 0.5kg |
| Digester Weight | 1.1kg |
| Carrying case Weight | 4.8kg |
Features
Suitable for on-site detection
Includes a digester
Interface for data transfer
Narrow-band interference optical system
Equipped with rechargeable lithium battery
Data power-off protection
Equipped with a high-strength suitcase
Strong and easy to carry
Anti-corrosive material
FAQs
1. Is Portable Multiparameter Water Quality Analyzer suitable for field use?
The Portable Multiparameter Water Quality Analyzer is designed for portability, its high-strength carrying case ensures durability and ease of transport. The Portable Multiparameter Water Quality Analyzer directly display the measurement values of , ammonia nitrogen, total phosphorus and total nitrogen, making it ideal for outdoor and on-site applications, including Drinking water analysis, Environmental monitoring, Wastewater treatment, Industrial process water and surface water treatment.
2. Which parameters does the Portable Multiparameter Water Quality Analyzer measure?
Portable Multiparameter Water Quality Analyzer utilizes sealed catalytic digestion followed by colorimetric measurement. It employs cold light source, narrow-band interference technology and microcomputer data processing to directly display the measurement values of Chemical Oxygen Demand (), ammonia nitrogen, total phosphorus and total nitrogen with indication error of less than or equal to 2%.
3. How does the Portable Multiparameter Water Quality Analyzer ensure measurement accuracy?
Portable Multiparameter Water Quality Analyzer utilizes cold light source and narrow-band interference optical system, providing excellent optical stability. It features a separate device and digester, which helps prevent interference and ensures accurate measurements. It uses anti-chlorine interference method. Anti-chlorine reagents do not interfere with measurements. They are formulated to neutralize only chlorine without reacting with organic compounds. Chlorine interference occurs when residual chlorine in water samples reacts during analysis, leading to falsely elevated values.
4. Does the Portable Multiparameter Water Quality Analyzer features data storage?
Portable Multiparameter Water Quality Analyzer stores up to 250 factory curves and up to 749 user curves and features data storage of 10,000records. The one-key factory reset function prevents loss of accidental deletion of curves. It provides interface, that allows data transfer to a computer, where it can be saved as files. It has data retention feature, which ensures data retention even during events of power outages.
5. What is the detection method used by the Portable Multiparameter Water Quality Analyzer ?
The Portable Multiparameter Water Quality Analyzer utilizes sealed catalytic digestion followed by colorimetric measurement for the automated measurement of water samples, providing reliable and consistent results of 4 samples per run, enhancing efficiency in field analysis. It features a separate device and digester, which helps prevent temperature interference and ensures accurate measurements.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.