Introduction

Single Station Glove Box offers 3 glove compartments and creates an ultra- clean atmosphere with impurity levels as low as 0.1 ppm. The gloves are made of butyl rubber for better grip and comfort. Additionally, the glove ports have a diameter 220 mm with O-ring seal to prevent leakage. Its advance sensors help to monitor chamber pressure accurately for better control. Our glove box mainly creates an ideal environment for working on sensitive materials in fields like 3D printing, biomedical research etc.

This glove box is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Our Single Station Glove Box  glove box system is designed to maintain a moisture and oxygen-free environment, making it ideal for sensitive applications. It supports biomedical research, electronic component handling, and is also used in industries such as nuclear and membrane technology.

Specifications

Number of Glove Ports 3
Gloves Material Butyl rubber
Glove Port Material Standard: Aluminum alloy
Glove Port Diameter 220 mm, O-ring sealed
Working Gas N₂, Ar, He (purity up to 99.999%)
Water & Oxygen Index Less than 0.1 ppm (with proper purification system)
Circulation Capacity 0 to 90 m³/h (oil-free high-speed fan)
Material 304 stainless steel, 3 mm thickness
Internal Dimensions 1500 × 760 × 900 mm
Window 8 mm safety tempered glass or 10 mm polycarbonate (optional)
Pressure Control Automatic pressure control with foot switch operation
Big Passing Box Equipped with heating system, temperature up to 200°C, accuracy ±1°C
Small Passing Box Optional (not specified, usually included in double-station setups)
Filter Inlet & outlet filters, filtration below 0.3 μm
Shelf 5-layer adjustable internal shelving (within refrigerator compartment)
Lighting Integrated lighting in upper window frame
Gas Purification Automatic H2O and O2 removal, closed-loop single-column (dual-column optional)
Purification Capacity Suitable for achieving up to 0.1 ppm H₂O and O₂ with continuous operation
Gas Cycling System Closed pipeline loop, oil-free recirculation fan
Regeneration Gas 5 to 10% H2mixed with working gas (purity more than or equals to 99.999%)
Vacuum Pump Rotary vane, 8 m³/h, vacuum is lower than 2×10⁻³ mbar, with oil mist filter and gas ballast
Main Valve Electromagnetic high vacuum valve
Control Valve High-sealing valves integrated into circulation and purge systems
Control System Fully automatic control, sensor-integrated, software-enabled
Foot Switch Yes, for pressure regulation and control
Display System Digital display for oxygen, moisture, pressure, and system status
Power Supply AC 230 V to 50–60 Hz to 10 A or AC 115 V to 50–60 Hz to20 A (optional)
Dimension (L×D×H) 1500 × 760 × 900 mm (internal workspace)
Overall Dimension 2235 × 935 ×1866 mm (with external systems attached)
Net Weight 520 Kg
Gross Weight 700 Kg

Features

Built-in recycle system

Convenient design

Caster wheel

light for better chamber visual

Thicker glove 

filters 

User friendly operation 

FAQs

1. What gases can be used in the Single Station Glove Box system?

Single Station Glove Box is compatible with inert gases such as nitrogen, argon, and helium perfect for maintaining a dry, oxygen-free environment. These gases help shield sensitive materials from unwanted reactions, moisture, or contamination. Depending on your specific application, you can choose the gas that best suits your process needs, ensuring a clean, stable, and controlled atmosphere for precision work in research, synthesis, or electronics handling.

2. What gases can be used in the glove box system?

Single Station Glove Box is compatible with inert gases such as nitrogen, argon, and helium—perfect for maintaining a dry, oxygen-free environment. These gases help shield sensitive materials from unwanted reactions, moisture, or contamination. Depending on your specific application, you can choose the gas that best suits your process needs, ensuring a clean, stable, and controlled atmosphere for precision work in research, synthesis, or electronics handling.

3. How does the Single Station Glove Box maintain pressure control?

Single Station Glove Box features an automated, -based pressure control system that keeps internal pressure slightly positive usually around ±15 mbar. This prevents ambient air from entering, protecting sensitive materials inside. The system responds quickly to changes caused by glove movements or airlock use, adjusting automatically to keep conditions stable. This ensures a consistent and safe environment for delicate tasks, even during frequent access or handling inside the glove box.

4. Can the items be transferred items in and out without contaminating the chamber?

Yes, the glove box includes both small and large antechambers for the safe transfer of materials. Items are first placed in the airlock, where they’re either evacuated or purged with inert gas before entering the main chamber. This careful process prevents outside air from entering, keeping oxygen and moisture levels extremely low. It ensures the internal environment stays stable and uncontaminated, even during frequent material transfers or sample handling.

5. What filtration and purification systems do the glove box use?

Single Station Glove Box features a dual-stage purification system with copper catalysts and molecular sieves that continuously remove oxygen and moisture. It also includes particulate filtration to eliminate dust and airborne contaminants. These systems work together to maintain an ultra-pure, inert atmosphere, essential for sensitive tasks like organo-metallic synthesis, lithium material handling, or electronics work. This ensures maximum protection for both the materials and the integrity of the experimental environment.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.