Introduction

-86°C Ultra Upright Freezer delivers temperature range from -40°C to -86°C for flexible and safe biological storage. The 730 cryo boxes for large-scale storage. An insulated 90 mm thick door enhances thermal stability during long-term cryogenic preservation. Equipped with casters and pressure balance port for smooth mobility and easy door operation. Ideal for long-term storage of biological samples in labs, hospitals, and research institutions.

This laboratory freezers is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Our Ultra Low-Temperature Upright Freezer is ideal for long-term cryogenic storage of biological materials like erythrocytes, virus cultures, and tissues. Suitable for research labs, blood banks, marine biology, and biopharmaceutical environments.

Specifications

Cabinet Type Upright
Capacity 730 L
Temperature Range -40°C to -86°C
Capacity for 2-Inch Boxes 500
Climate Class N
Cooling Type Direct cooling
Defrost Mode Manual
Refrigerant R290 / R170
Cooling Performance -80°C
Exterior Material Galvanized steel powder coating
Interior Material Galvanized steel powder coating
Insulation Material +
Thickness of Door 90 mm
Inner Door Number 2
Low/High Temperature Alarm Yes
Condenser High Temperature Alarm Yes
Power Failure Alarm Yes
Sensor Failure Alarm Yes
Alarm Mode Sound and light, remote terminal
Caster Yes
Test Hole Yes
Temperature Recorder Yes
Door Locking Device Yes
Handle Yes
Pressure Balance Hole Yes
Thickness of Cabinet Foamed Layer 90 mm
Power Supply 220 V / 50 Hz
Power 1000 W
Energy Consumption 14.5 kWh/24h
Interior Dimensions (W×D×H) 740 × 730 × 1310 mm
Exterior Dimensions (W×D×H) 995 × 985 × 1980 mm
Package Dimensions (W×D×H) 1015 × 1020 × 2190 mm
Net Weight 297 kg
Gross Weight 332 kg

Features

Hydrocarbon refrigerant system

Dual inner door design

Galvanized steel cabinet

Manual defrost mode

Adjustable stainless shelves

Integrated temperature recorder

Visual and audible alarms

Pressure balance mechanism

FAQs

1. What materials can be safely stored in the -86°C Ultra Low-Temperature Upright Freezer?

The -86°C Ultra Low-Temperature Upright Freezer is ideal for storing erythrocytes, virus cultures, tissue samples, and vaccines. It provides a controlled cryogenic environment for sensitive biological and pharmaceutical materials. design supports reliable long-term preservation in research and clinical settings. The freezer is also suitable for enzymes and other reagents requiring ultra-low storage.

2. How easy is it to move the -86°C Ultra Low-Temperature Upright Freezer within the lab?

-86°C Ultra Low-Temperature Upright Freezer features heavy-duty casters for smooth mobility within laboratory environments. A pressure-balanced port ensures effortless door operation during relocation. The unit’s stable build allows safe repositioning without compromising temperature control. This makes it convenient for dynamic lab layouts or shared facilities.

3. How does the -86°C Ultra Low-Temperature Upright Freezer ensure safe storage of biological samples?

The -86°C Ultra Low-Temperature Upright Freezer is equipped with multiple alarm systems, including alerts for high/low temperature, power failure, and sensor errors. It uses both audible and visual indicators, as well as optional remote alarm notifications. A built-in battery backup supports monitoring during power outages. The freezer also features a lockable door to restrict unauthorized access.

4. Can the -86°C Ultra Low-Temperature Upright Freezer handle frequent door openings during sample retrieval?

The -86°C Ultra Low-Temperature Upright Freezer includes double inner doors and a pressure balance port to reduce temperature loss during access. A door-open alarm activates when the door remains open for too long. These features help maintain consistent internal temperatures during frequent sample handling. This design is ideal for labs with high access requirements.

5. What should users consider when installing the -86°C Ultra Low-Temperature Upright Freezer?

-86°C Ultra Low-Temperature Upright Freezer must be installed in a well-ventilated space with at least 50 mm of clearance on all sides. Avoid placing it near direct heat sources or in areas with high humidity. Proper installation on a level surface ensures door sealing and efficient drainage. These steps help ensure the freezer operates effectively over time.

6. How is temperature accuracy maintained in the -86°C Ultra Low-Temperature Upright Freezer?

-86°C Ultra Low-Temperature Upright Freezer uses a digital control system coupled with a high-efficiency cascade refrigeration circuit for precise temperature management. Temperature settings can be easily adjusted via a password-protected interface. Continuous monitoring is provided through real-time displays and alarms for any temperature deviation. This guarantees that stored materials are kept at optimal conditions.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.