Xenon offers a wavelength range of 190 to 1100 nm and spectral bandwidth range of 0.1, 0.2, 0.5, 1, 2, 4 and 5 nm.Its high-quality flashing xenon lamp allows instant testing without the need for preheating. The spectrophotometer features an 11-inch touchscreen, enhances user experience. It supports direct connectivity to a laser via Wi-Fi and to a thermal printer via Bluetooth. Our spectrophotometer with versatility and precision, it is ideal for both quantitative and qualitative analysis across scientific and industrial applications.
This analytical equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
It’s Xenon Lamp Spectrophotometer is designed to meet the diverse needs of laboratories and industries.It supports a wide range of analytical functions such as photometric and quantitative measurements, kinetics studies, spectrum scanning, /protein analysis, and multi-wavelength testing. Additionally, it plays a vital role in drug formulation, environmental monitoring, and toxicology analysis.
Specifications
| Wavelength Range | 190 to 1100 nm |
| Spectral Bandwidth | 0.1, 0.2, 0.5, 1, 2, 4 and 5 nm |
| Optical System | Double Beam, Grating 1200 lines/ mm |
| Wavelength Accuracy | ± 0.3 nm |
| Wavelength Repeatability | Up to 0.1 nm |
| Photometric Accuracy | ±0.2% T (0 to 100% T), ±0.0005 A (0 to 0.5 A), ±0.0008 A (0.5 to 1 A) |
| Photometric Repeatability | Up to 0.15% T (0 to 100% T), 0.0004 A(0 to 0.5 A), 0.0006 A (0.5 to 1 A) |
| Photometric Range | 0 to 400% T, -4 to 4 A |
| Resolution | 0.00001Abs |
| Stray Light | Up to 0.03% T at 220 nm, 360 nm |
| Stability | ± 0.0001A |
| Baseline Flatness | ±0.0004 A |
| Noise | 0.0005A at 500 nm |
| Work Mode | T, A, C, E |
| Scanning Speed | Hi, Med, Low (Max. 6000 nm/min) |
| Display | 11-inch Touch Screen |
| Light Source | Imported xenon lamp |
| Detector | Imported Silicon Photodiode |
| Cuvette Holder | 10 mm single hole cell holder |
| Output | Cloud connectivity/Email//Bluetooth/WiFi |
| Power Supply | AC 110 to 220V 50 to 60Hz |
| Dimensions | 880 × 690 × 520 mm |
| Gross Weight | 45kg |
Features
/ compliance
Real-time sharing of data
Bluetooth connectivity
Different work modes
Various scanning speeds
FAQs
1. What is the spectral bandwidth range of the Xenon lamp spectrophotometer?
Xenon lamp spectrophotometer features a variable spectral bandwidth of 0.1, 0.2, 0.5, 1, 2, 4, and 5 nm. This feature allows users to select the optimal bandwidth for specific applications, ensuring high precision and accuracy in measurements. It ensures adaptability across various scientific and industrial fields, including pharmaceuticals, environmental monitoring, biotechnology, and material sciences.
2. Does this Xenon lamp spectrophotometer support data transfer options?
Yes. Xenon lamp spectrophotometer supports multiple data transfer options. It includes Real-time sending of data via mail and mobile . Also it adopts 3.0 Bluetooth provides stable transmission and free interconnection within 10 meters. The cloud connectivity and Wi-Fi options available for seamless data sharing and remote access. This allows users to easily transfer and store measurement data for further analysis.
3. What standard accessories are included with the Xenon lamp spectrophotometer?
Xenon lamp spectrophotometer comes with a set of essential accessories for immediate use. It includes four 10 mm glass cuvettes, two 10 mm quartz (UV) cuvettes, and a power cord. The glass cuvettes are ideal for measurements within the visible range (400–700 nm), commonly used for colorimetric and general spectrophotometric analyses. The quartz cuvettes are designed for UV-range measurements (below 400 nm), as quartz allows UV light to pass through, making them suitable for applications such as nucleic acid, protein, and other UV-based analyses. The included power cord ensures reliable electrical connectivity for operating the instrument.
4. Does this xenon flashing lamp in the Xenon lamp spectrophotometer require pre-heating?
No, Xenon lamp spectrophotometer does not require preheating. Unlike traditional light sources such as tungsten or deuterium lamps, which often need a warm-up period to stabilize, xenon flash lamps are designed to operate instantly upon activation. This immediate readiness not only saves time but also improves workflow efficiency in laboratory settings. Since the lamp only emits light during measurements, it experiences less wear and tear, contributing to a longer operational life and more consistent performance.
5. Does this Xenon lamp spectrophotometer support different work modes?
Yes. Xenon lamp spectrophotometer offers a variety of working modes, providing the flexibility needed to accommodate a wide range of analytical applications. The Transmittance mode (T) measures the percentage of light that passes through a sample, while the Absorbance mode (A) determines how much light is absorbed at a specific wavelength. For quantitative analysis, the Concentration mode (C) enables users to calculate sample concentrations based on a predefined calibration curve. Additionally, the Energy mode (E) measures the energy of the light transmitted through the sample.