Introduction
Automatic features a 3 L evaporation flask ideal for moderate-scale solvent removal in research labs. Its condensing surface accelerates vapour cooling and enhances solvent recovery. The system runs on a reliable power supply suitable for standard laboratory settings. Our Automatic Lifting Rotary Evaporator enables efficient distillation and sample concentration in analytical and research laboratories.
This equipment is essential for solvent evaporation and concentration processes in chemical, pharmaceutical, and food laboratories. It features efficient heat transfer and vacuum control to ensure optimal distillation results while protecting sensitive samples.Applications
Manual Lifting Rotary Evaporator performs solvent removal and concentration through adjustable rotation and gentle heating. Used in academic, chemical, and pharmaceutical laboratories for distillation, extraction, and compound purification.
Specifications
| Evaporating Flask | 3 L |
| Receiving Bottle | 2 L |
| Rotation Speed | 0 to 120 rpm |
| Lifting Distance | 200 mm |
| Lifting Mode | Manual |
| Temperature Range | RT to 180°C |
| Temperature Control Accuracy | +/- 1°C |
| Vacuum Degree | 0.098 Mpa |
| Condensing Area | 0.26 m2 |
| Rotating Motor Power | 40 W |
| Heating Power | 2000 W |
| Bath Capacity | 8.8 L |
| Power Consumption | 2040 W |
| Power Supply | 220 to 240 V,5O Hz |
| Dimensions (L×W×H) | 740×330×970 mm |
| Weight | 23 Kg |
Features
Variable pressure sealing
Low-noise motor drive
Quick-change flask joints
Anti-splash design
Broad temperature range
FAQs
1. What kind of solvents can the Manual Lifting Rotary Evaporator handle in laboratory settings?
The Manual Lifting Rotary Evaporator is compatible with a wide range of solvents used in chemical, academic, and pharmaceutical laboratories. It can process low-boiling alcohols as well as more complex organic mixtures. The vacuum system enables low-temperature evaporation to protect heat-sensitive compounds. Borosilicate glass construction offers chemical durability across repeated use. The condenser enhances vapour collection efficiency and solvent recovery. Temperature and rotation settings allow flexibility for different solvent properties. It handles routine concentration tasks with consistency. This makes it suitable for solvent recovery in research and quality control environments.
2. How does Manual Lifting Rotary Evaporator improve operational control in a laboratory?
Manual Lifting Rotary Evaporator provides complete control of rotation speed, heating levels, and vertical adjustment. It allows technicians to fine-tune evaporation conditions based on sample requirements. The rotation speed range of 0 to 120 rpm ensures consistent mixing. A temperature control accuracy of ±1°C supports reproducible results. Manual lifting simplifies flask immersion without mechanical complications. The heating system is powerful enough for rapid thermal response. All controls are accessible from the front for easy handling. It suits laboratories needing reliable manual operation for daily use.
3. What are the installation requirements for using a Manual Lifting Rotary Evaporator?
Manual Lifting Rotary Evaporator should be installed on a level, well-ventilated bench in a laboratory environment. It requires a power supply of 220 to 240 V at 50 Hz and a connection to a vacuum pump. Water access for the condenser coil is necessary for effective cooling. Adequate space is needed for safe movement during flask lifting and rotation. Collection vessels must be positioned correctly to avoid spillage. No special furniture or wiring is needed for installation. The design allows for fast setup without tools. It is easy to incorporate into standard laboratory workflows.
4. What makes the Manual Lifting Rotary Evaporator suitable for compound purification?
The Manual Lifting Rotary Evaporator supports compound purification through controlled vacuum evaporation. Its temperature stability protects sensitive compounds from breakdown. The rotation system promotes even heat distribution and smooth solvent removal. A 3 L evaporating flask and a 2 L receiving bottle are suitable for batch extractions. Borosilicate components withstand chemical exposure during purification. The 8.8 L heating bath offers sufficient volume for extended procedures. The vacuum level of 0.098 Mpa supports thorough drying. performs reliably in demanding compound separation applications.
5. How does our Manual Lifting Rotary Evaporator contribute to energy-efficient laboratory operations?
Manual Lifting Rotary Evaporator supports energy-conscious workflows through thoughtful power management. A 2000 W heater provides quick thermal response without unnecessary cycling. The manual lifting mechanism reduces dependence on powered vertical systems. Accurate control reduces heating time and avoids overheating. The condenser works effectively at low coolant flow rates. A 40 W rotation motor minimizes energy draw during continuous use. Insulated design reduces power losses during evaporation. These features help reduce long-term energy consumption in research environments.
6. Why is the Manual Lifting Rotary Evaporator a preferred choice for academic laboratories?
The Manual Lifting Rotary Evaporator is often selected by academic institutions for its ease of use and durable design. Manual controls allow students to understand each step of solvent removal. The setup includes visible glass components for real-time observation. Compact dimensions suit shared laboratory benches. Maintenance requirements are minimal, reducing downtime. It offers dependable performance under regular instructional use. Safety features make it suitable for supervised training settings. The model is widely adopted in educational laboratories for its consistent results.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

