Introduction

Manual features a 1 L flask ideal for mid-scale solvent processing in research labs. Its variable rotation promotes efficient film formation, speeding up evaporation. The chemical-resistant sealing system ensures vacuum stability and contamination-free operation. Our Manual Lifting Rotary Evaporator supports reliable solvent removal in pharmaceutical and chemical laboratories.

This equipment is essential for solvent evaporation and concentration processes in chemical, pharmaceutical, and food laboratories. It features efficient heat transfer and vacuum control to ensure optimal distillation results while protecting sensitive samples.

Applications

Manual Lifting Rotary Evaporator enables controlled solvent evaporation, concentration, and purification of heat-sensitive compounds. It is widely applied in chemical development, pharmaceutical formulation, and botanical extraction laboratories.

Specifications

Evaporating Flask 1 L
Receiving Bottle 1 L
Rotation Speed 0 to 120 rpm
Lifting Distance 200 mm
Lifting Mode Manual
Temperature Range RT to 180°C
Temperature Control Accuracy +/- 1°C
Vacuum Degree 0.098 Mpa
Condensing Area 0.17 m2
Rotating Motor Power 40 W
Heating Power 1200 W
Bath Capacity 6.6 L
Power Consumption 1240 W
Power Supply 220 to 240 V,5O Hz
Dimensions (L×W×H) 750×360×1060 mm
Weight 32 Kg

Features

Optimised motor power output

Energy-efficient heating element

Standard power compatibility

Large bath capacity

Stable frame construction

FAQs

1. What type of materials are compatible with the Manual Lifting Rotary Evaporator?

Manual Lifting Rotary Evaporator is compatible with a wide variety of solvents used in analytical and research labs. Its borosilicate glassware resists thermal stress and chemical corrosion. The and fluoro rubber sealing components withstand aggressive vapours and strong acids. The system supports both volatile and stable compounds without compromising safety. It performs reliably with organic, aqueous, and low-boiling materials. Suitable for chemical synthesis and purification applications. It can be used confidently across academic and industrial workflows. The components are engineered for durability and repeated solvent exposure.

2. How energy-efficient is the Manual Lifting Rotary Evaporator during continuous use?

The It Manual Lifting Rotary Evaporator operates with energy-conscious features that support long-term usage. Its 1240 W total power rating includes a 1200 W heating bath optimised for stable performance. Vacuum control shortens operation time by enabling low-boiling-point evaporation. Its consistent heating helps reduce repeated cycles and energy spikes. The compact structure minimises thermal loss and supports temperature retention. The system’s power design avoids unnecessary consumption between runs. The model is a dependable choice in labs with high equipment usage. It balances daily demands with operational efficiency.

3. Can the Manual Lifting Rotary Evaporator handle viscous or dense liquids?

The Manual Lifting Rotary Evaporator is designed to support moderately viscous materials during evaporation. Its adjustable rotation improves film formation and ensures uniform exposure for thicker liquids. The It heating bath helps reduce fluid resistance through gradual temperature increases. High vacuum efficiency aids in handling dense or oily samples without splashing. seals maintain suction, even during slow rotations. The unit is not intended for extremely thick polymers but suits extract and concentrates. It supports a broad range of applications from botanical processing to compound purification. Reliable control prevents bubbling or loss of valuable samples.

4. Is the Manual Lifting Rotary Evaporator suitable for academic laboratories?

Manual Lifting Rotary Evaporator provides a hands-on solution for teaching laboratories and practical training environments. It features mechanical controls that make it easy for students to operate without complex software. The clear borosilicate setup allows learners to observe evaporation and condensation in real-time. Compact design enables bench-top use in shared or space-constrained settings. Vacuum and heating adjustments support entry-level experiments. The model is often selected for chemistry practical sessions and capstone projects. It offers a safe and accessible interface for basic lab demonstrations. Its design ensures both usability and instructional value.

5. How does the Manual Lifting Rotary Evaporator minimise sample loss during evaporation?

Manual Lifting Rotary Evaporator helps limit the loss of solvents and compounds throughout evaporation. The system's closed structure and tight seals maintain a stable vacuum, protecting samples from leaks. Its vertical condenser provides rapid vapour cooling, aiding clean collection. Even rotation prevents sample bumping and maintains uniform exposure to heat. The heating bath promotes consistent evaporation with reduced residue formation. users benefit from improved recovery of both low- and mid-boiling-point substances. The glass interface supports a steady workflow for daily or batch-based procedures. This setup ensures effective solvent removal with minimal waste.

6. Can the Manual Lifting Rotary Evaporator be used for daily lab operations?

The It Manual Lifting Rotary Evaporator is built to withstand frequent laboratory use without performance decline. Its 32 kg frame and rigid build make it stable during continuous handling. Standard 1 L flask capacities support typical daily solvent processing needs. The system heats quickly and retains vacuum conditions across repeated runs. Easy manual adjustments reduce setup time between experiments. Vacuum sealing ensures sample integrity throughout operation. The is frequently used in pharmaceutical and industrial chemistry labs. It provides consistency and reduces downtime in multi-shift lab environments.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.