Introduction
Horizontal includes efficient heating elements allowing rapid sterilization cycles within temperature range of 105℃ to 138℃. Its advanced microprocessor controller enables thermal and pressure regulation efficiently. Feature automatic pressure release valve that ensures operator safety and prevents overpressure situations. The digital display provides real-time monitoring of heating, pressure, and cycle status. Offers safety interlock mechanism to prevent accidental door opening during high-pressure operations.
It uses high-temperature and high-pressure steam to achieve effective sterilization of laboratory equipment, media, and waste. The advanced control system ensures thorough sterilization while preventing overheating or pressure buildup.Applications
Our Horizontal Laboratory Autoclave provides efficient sterilization with precise temperature control, vacuum drying, and automatic operation, making it ideal for laboratories, medical facilities, and research applications.
Specifications
| Capacity | 150L |
| Design Temperature | 150℃ |
| Working Temperature Range | 105℃ to 138℃ |
| Working Pressure Range | 0 to 0.25 MPa |
| Steam Consumption | 12Kg per cycle |
| Water Consumption | 80Kg per cycle |
| Temperature Control Accuracy | ≤ ± 0.2℃ |
| Temperature Display Accuracy | 0.1℃ |
| Sterilization and Drying Time | 0 to 999 min |
| Vacuum Rate | -97 KPa |
| Temperature Equilibrium | Less than or equal to ± 0.5℃ |
| Safety Valve Open Pressure | 0.28 MPa |
| Water Source | 0.15 to 0.3 MPa |
| Steam Pressure | 0.3 to 0.6 MPa |
| Compressed Air Source | 0.4 MPa to 0.7 MPa |
| Control System | Siemens + + Printer |
| Display | 7-inch color touch screen |
| Loading System | Loading cart + Transfer trolley |
| Power Consumption | 14Kw |
| Power Supply | 220/380V, 50/60Hz |
| Internal Dimension (W×D×H) | 450mm×450mm×750mm |
| External Dimension (W×D×H) | 1190mm×1700mm×1100mm |
| Packaging Dimension (W×D×H) | 1400mm×1950mm×1550mm |
| Net Weight | 550kg |
| Gross Weight | 880kg |
Features
Front loading fully automatic
Automatic vertical sliding double door
Liquid ring vacuum pump, Pre-vacuum and Post-vacuum
Compatible Soft, purified and deionized water
Uses external steam source
Includes Built-in feeding pump and water tank
aided design
Finite Element Analysis
Triple-Layer Structure
Automatic Plasma Welding
Advanced Insulation Layer
Pneumatic Sealing Door
Intelligent Control System
Medical-Grade Pipelines
Efficient Vacuum System
Comprehensive Alarm System
Remote Monitoring Capability
FAQs
1. What is the recommended sterilization cycle for different types of laboratory materials?
The recommended cycle depends on the material type: 1) For glassware and heat-resistant materials: 121°C, 15-20 psi, for 15-20 minutes; 2) For liquid media: 121°C, 15-20 psi, for 20-30 minutes (longer for larger volumes); 3) For wrapped instruments: 121°C, 15-20 psi, for 25-30 minutes to ensure steam penetration; 4) For waste materials: 132°C, 30 psi, for 30 minutes for biohazardous waste; 5) For heat-sensitive materials: Use a lower temperature (115°C) for a longer duration (30 minutes) or a specialized cycle if available. Always refer to the material manufacturer's recommendations.
2. How to properly load the autoclave to ensure effective sterilization?
Proper loading is crucial: 1) Place items in a way that allows steam to circulate freely around all surfaces; 2) Avoid overloading the autoclave chamber, leaving at least 2-3 inches of space between items; 3) Stack items with openings facing downward to prevent water accumulation and ensure steam penetration; 4) Use autoclave-compatible containers and avoid sealing them tightly (leave lids loose or use vented caps); 5) Separate different types of materials if possible, especially liquids and solids; 6) Ensure that liquid containers are not filled more than 2/3 full to prevent boiling over.
3. What maintenance procedures are required for the autoclave?
Regular maintenance includes: 1) Draining and cleaning the water reservoir after each use to prevent mineral buildup; 2) Descaling the autoclave monthly (or more frequently in hard water areas) using a recommended descaling agent; 3) Inspecting the door gasket for wear, cracks, or damage and replacing it if necessary; 4) Checking the pressure relief valve and safety interlocks quarterly to ensure proper operation; 5) Cleaning the chamber interior with a mild detergent after each use; 6) Performing annual calibration of temperature and pressure gauges by qualified personnel; 7) Keeping a maintenance log to track all service activities.
4. How to troubleshoot if the autoclave fails to reach the desired temperature or pressure?
If temperature/pressure issues occur: 1) Check if the water level in the reservoir is sufficient; 2) Verify that the door is properly closed and sealed (check gasket for damage); 3) Inspect the heating element for signs of malfunction; 4) Check the pressure relief valve to ensure it is not stuck open; 5) Clean the steam vents and drains to remove any blockages; 6) Ensure the autoclave is properly grounded and the power supply is stable; 7) If the problem persists, do not use the autoclave and contact technical support immediately, as it may pose a safety risk.
5. What safety precautions should be followed when operating the autoclave?
Important safety precautions: 1) Never open the autoclave door while it is pressurized or during the sterilization cycle; 2) Allow the autoclave to cool down and depressurize completely before opening; 3) Wear heat-resistant gloves and eye protection when handling hot items; 4) Stand to the side of the autoclave when opening the door to avoid steam burns; 5) Never autoclave incompatible materials (such as volatile solvents, oils, or explosives); 6) Regularly test the autoclave's performance using biological indicators (spore tests) to ensure effective sterilization; 7) Familiarize yourself with the emergency stop procedures and location of safety devices.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

