Introduction

Double-Stage Vacuum Transformer Oil Purifier operates with a high flow rate of 1800 control system to prevent foam formation during degassing. Equipped with interlocked protections linking the oil pump, heater, and liquid sensor to prevent dry heating. Our vacuum transformer oil purifier operates with low noise levels, ensuring a quiet working environment.

This petroleum testing is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Double-Stage Vacuum Transformer Oil Purifier is used to purify transformer oil by removing moisture, gases, and impurities, improving dielectric strength. It is widely used in power plants, substations, and industrial facilities for maintaining transformers and electrical equipment.

Specifications

Flow Rate 1800 L/H
Vacuum Degree -0.08 to -0.099 MPa
Vacuum Pressure ≤ 0.3 MPa
Temperature Range 20 to 80℃
Working Noise 68 dB(A)
Oil Outlet/Inlet Φ 25 mm
Moisture Content ≤3
Gas Content 0.1 %
Impurity Size ≤1 μm
Value β 98 %
Cleanness ≤ 6
Heating Power 24,000 W
Power Consumption 27,000 W
Power Supply AC380V/50Hz/3
Dimensions (L×W×H) 1550 × 1100 × 1850mm
Net Weight 550 kg
Gross Weight 600 kg

Features

Automatic filter monitoring

Integrated vacuum pump system

Multi-pass processing capability

Advanced temperature control

Built-in data recording

FAQs

1. How does the automatic anti-foam control system in the Double-Stage Vacuum Transformer Oil Purifier enhance its operation?

Double-Stage Vacuum Transformer Oil Purifier features an automatic anti-foam control system that prevents foam formation during the degassing process. This ensures smooth and uninterrupted operation, enhancing the efficiency, safety, and reliability of transformer oil purification. It also helps maintain consistent vacuum levels, protects internal components from operational disruptions, and prolongs the overall service life of the equipment while reducing the need for manual intervention.

2. What safety features are integrated into the Double-Stage Vacuum Transformer Oil Purifier?

Double-Stage Vacuum Transformer Oil Purifier is equipped with interlocked protections linking the oil pump, heater, and liquid sensor to prevent dry heating. These safety features ensure reliable and safe operation during the oil purification process by automatically shutting down critical components in abnormal conditions. This not only safeguards the system from damage but also minimizes downtime, enhances user safety, and extends the lifespan of the equipment.

3. How does the infrared liquid level control in the Portable Oil Purification System function?

Maintains precise control over fluid dynamics, ensuring uninterrupted oil flow throughout the purification process. Prevents overflows and dry runs, protecting internal components from damage due to irregular oil levels. Enhances system automation, reducing the need for manual monitoring, adjustments, and operator intervention. Contributes to the overall reliability, consistency, and long-term operational safety of our Portable Oil Purification System during continuous and demanding industrial applications.

4. What makes the Double-Stage Vacuum Transformer Oil Purifier suitable for high-demand industrial operations?

Double-Stage Vacuum Transformer Oil Purifier operates at a high flow rate of 1800 L/H, which allows for fast and efficient purification in large-scale facilities. Its built-in vacuum system, automatic filter monitoring, and advanced temperature control ensure continuous high performance in demanding environments. The dual-stage vacuum enhances degassing and dehydration efficiency, making it ideal for transformers under heavy load or critical operation. Additionally, its integrated safety interlocks and anti-foam technology contribute to smooth, uninterrupted operation, minimizing downtime and maintenance needs.

5. How does the automatic anti-foam control system in the Double-Stage Vacuum Transformer Oil Purifier enhance its operation?

The Double-Stage Vacuum Transformer Oil Purifier features an automatic anti-foam control system that prevents foam formation during the degassing process. This ensures smooth and uninterrupted operation, enhancing the efficiency of transformer oil purification. By actively controlling foam levels, the system avoids spillage and pressure fluctuations that could disrupt the purification cycle. This feature is especially valuable during high-volume or long-duration operations, where consistent performance and equipment safety are critical.

6. Is the Double-Stage Vacuum Transformer Oil Purifier easy to monitor and operate?

Yes, our Double-Stage Vacuum Transformer Oil Purifier includes integrated monitoring systems and automatic controls. The system provides real-time data on temperature, vacuum, and filter status, ensuring user-friendly operation and minimal manual intervention. Operators can easily track performance and receive alerts for maintenance or anomalies, reducing the risk of operational errors. This intelligent control setup not only improves efficiency but also extends the service life of both the purifier and the transformer equipment it supports.