Introduction

Single Automated Stainer Fluorescence processes up to 12 slides, ensuring high-throughput and workflow automation with proper luminescence. The built-in slide heating system ensures uniform temperature distribution for optimized radiance binding. Its high-resolution optical sensors ensure accurate reagent level detection and automatic refill alerts. Provide advanced safety features including spill detection, emergency stop and containment system. Offers minimal hands-on operation reduces technician workload and fatigue.

This automated stainers is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Our Single Automated Stainer Fluorescence F enhances research, diagnostics, and pathology workflows by providing precise, automated fluorescence staining with customizable settings, high throughput, and advanced imaging capabilities.

Specifications

Slide Tray Capacity 12 slides (single processing)
Slide Installation Vertical
Staining Methods Vaginal Discharge Fluorescence
Open Lid Height 580mm
Staining Capacity ≧ 144 slides per hour
Staining Time 4 to 5 minutes
Reagent Capacity 4×500 per bottle stain 600ml to 1200 slides
Reagent Heating Adjustable to 65°C to 85°C
Heats in 10 minutes
Cold dyeing in 14.5min
Reagent Management Independent reagent pathways to prevent cross-contamination
Staining Grade Carbon red: Level 6
Acid alcohol: Level 6
Methylene Blue: Level 6
User Interface 7-inch ultra large display
Safety Mechanism Operates only when lid is closed
Status shown on indicator light
Standards Compliance GB4793.1, GB18268.1, GB18268.26, YY0648, GB/T14710
Power Consumption DC motor
Power Supply 220VAC, 50 to 60Hz
Dimension (W×D×H) 550mm × 250mm × 550mm
Weight 20kg

Features

Fully Automated Operation

Spray Staining Principle 

Multiple Staining Levels

Large Sample Processing Capacity 

User-Friendly Operation 

FAQs

1. What are the key factors to consider when selecting this automated stainers for laboratory use?

When selecting this automated stainers, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this automated stainers be calibrated to ensure accurate results?

It is recommended to calibrate this automated stainers at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this automated stainers?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this automated stainers be used with different types of samples, and are there any compatibility considerations?

Yes, this automated stainers can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the automated stainers malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.