Introduction

Automatic Biochemistry Analyzer handles sample sizes ranging from 2 to 50μL with precise 0.1μL incremental adjustments. Designed with user-friendly interface for seamless programming and operation. Equipped with advanced sensors for real-time monitoring and error detection. Integrated high-resolution display ensures clear and precise data visualization. Ensures optimal reproducibility for consistent results across multiple analyses.

This medical equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Our Automatic Biochemistry Analyzer is designed for high-speed biochemical analysis of blood, serum, and urine samples, making it ideal for clinical diagnostics, research, and routine laboratory use.

Specifications

Detection Speed 100 tests per hour
Wavelength 9 wavelengths, 340nm to 700nm
Sample Size 2 to 50μL, 0.1μL increments
Absorbance Range 0 to 4.8 Abs
Reagent Reagent 1: 100 to 450μL, 0.1μL increments
Reagent 1: 0 to 200μL, 0.1μL increments
Integrated Touch Screen 10.4 inch color
Sample Racks 5-hole or 9-hole
Reagent Warehouse 2°C to 8°C, 45 reagent positions
Reaction Cup Maintenance 80 pieces, one-time use
Dimension (W×D×H) 540 mm × 328 mm × 515 mm
Net Weight 35 kg

Features

Compact, space-saving design

Optional sample racks

Supports multiple tubes

Automatic sample dilution

Continuous sample addition

Partition-free reagent placement

QR-coded reagent bottles

24-hour refrigeration support

Customizable test menu

FAQs

1. What are the key factors to consider when selecting this medical equipment for laboratory use?

When selecting this medical equipment, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this medical equipment be calibrated to ensure accurate results?

It is recommended to calibrate this medical equipment at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this medical equipment?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this medical equipment be used with different types of samples, and are there any compatibility considerations?

Yes, this medical equipment can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the medical equipment malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.