Laser Particle Size Analyzer measures particle sizes from 0.01μm to 2000μm, providing accurate analysis for a wide range of samples. It features a high-performance semiconductor laser with dual-laser technology for enhanced precision. The analyzer integrates ultrasonic dispersion at 40KHz and mechanical stirring with adjustable speed from 0 to 3000 . Its built-in automatic wet dispersion system ensures uniform particle distribution during testing. Ideal for laboratory environments requiring rapid, reliable, and automated particle size analysis.
This analytical equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Our Laser Particle Size Analyzer is designed for research labs, quality control, and industries dealing with fine particles, including pharmaceuticals, chemicals, cement, ceramics, paints, and food.
Specifications
| Dispersion Type | Wet |
| Measurement Range | 0.01μm to 2000μm |
| Channel Number | 116 |
| Accuracy Error | <1% (National Standard Sample D50) |
| Repeatability Error | <1% (National Standard Sample D50) |
| Stir | Revolutions Speed: 0 to 3000RPM (Adjustable) |
| Light Source | semiconductor laser (λ=632.8nm, P>4.0MW) |
| Auxiliary Light Source | Semiconductor laser (λ=650nm, P>10MW) |
| Sample Pool Volume | 1L |
| Test Speed | <2mins per test |
| Ultrasonic | Frequency: 40KHz, Power: 50W |
| Circulate | Rated Flow: 30L/min, Rated Power: 70W |
| Operation Mode | Full automatic software control |
| Dimensions | 1060 × 460 × 540 mm |
| Packing Dimensions | 1230 × 640× 660 mm |
| Net Weight | 58kg |
| Gross Weight | 88kg |
Features
Compact and Space-Saving Design
Fast testing time under 2 minutes
Intelligent one-touch operation
Multiple analysis modes
Automatic self-test monitoring
Customizable particle size outputs
Integrated water overflow safeguard
FAQs
1. What are the key factors to consider when selecting this analytical equipment for laboratory use?
When selecting this analytical equipment, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.
2. How often should this analytical equipment be calibrated to ensure accurate results?
It is recommended to calibrate this analytical equipment at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.
3. What are the common maintenance procedures required for this analytical equipment?
Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.
4. Can this analytical equipment be used with different types of samples, and are there any compatibility considerations?
Yes, this analytical equipment can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.
5. What should be done if the analytical equipment malfunctions or produces inconsistent results?
If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.