Introduction
Single Automated Wright Stainer operates with 16-slide capacity, ensuring efficient, high-throughput laboratory staining processes. Its user-friendly interface simplifies programming and enhances the workflow. The automatic slide loading and unloading minimize manual intervention during operation. Feature real-time monitoring display to process status for quick troubleshooting and workflow optimization. Offers robust electronic components ensuring reliable performance even under intensive use.
This automated stainers is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Our Single Automated Wright Stainer W streamlines slide preparation with customizable protocols, ensuring precise and efficient staining for hematology, pathology, and diagnostic applications in clinical and research laboratories.
Specifications
| Staining Methods | Wright Stainer |
| Slide Installation | Horizontal |
| Slide Tray Capacity | 1 to 16 |
| Open Lid Height | 580mm |
| Staining Capacity | 16 slides at one time |
| Staining Time | Blood: 10 minutes Bone Marrow: 22 minutes Chromosomes: 7 minutes |
| Reagent | Liquid A and Liquid B |
| Dyeing Level | Mix Liquid A and Liquid B in 1:1 to 1:7 |
| Dye Solution | 500ml per bottle Blood: 300 to 500 slides Bone marrow: 200 to 400 slides Chromosomes: 800 to 1600 slides |
| Reagent Management | Independent reagent pathways to prevent cross-contamination |
| Staining Grade | 25 levels Blood Staining: Level 6 to 8 Bone Marrow Staining: Level 18 to 25 |
| User Interface | 7-inch ultra large display |
| Cleaning | Alcohol cleaning Specialized pipeline cleaning Spray volume detection |
| Safety Mechanism | Operates only when lid is closed Status shown on indicator light |
| Standards Compliance | GB4793.1, GB18268.1, GB18268.26, YY0648, GB/T14710 |
| Power Consumption | DC motor |
| Power Supply | 220VAC, 50 to 60Hz |
| Dimension (W×D×H) | 550mm × 250mm × 550mm |
| Weight | 20kg |
Features
Minimal reagent evaporation design
Accurate timing mechanism ensured
Color-coded reagent system
Simple software calibration options
Optimized reagent application technique
Robust slide handling mechanism
FAQs
1. What are the key factors to consider when selecting this automated stainers for laboratory use?
When selecting this automated stainers, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.
2. How often should this automated stainers be calibrated to ensure accurate results?
It is recommended to calibrate this automated stainers at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.
3. What are the common maintenance procedures required for this automated stainers?
Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.
4. Can this automated stainers be used with different types of samples, and are there any compatibility considerations?
Yes, this automated stainers can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.
5. What should be done if the automated stainers malfunctions or produces inconsistent results?
If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

