Introduction

Horizontal Tissue Grinder offers a maximum feed size of up to 8 mm. The feed material can range from hard, medium-hard, and soft to brittle, elastic, and fibrous. It is designed with two grinding stations to accommodate efficient and versatile processing. Our Horizontal Tissue Grinder can process sample in a very short time without causing significant heating. The system allows for comfortable low-temperature grinding, ensuring sample integrity is maintained during processing. This tissue grinder is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Horizontal Tissue Grinder is ideal for fine grinding hard and brittle samples, as well as soft, elastic, and fibrous materials.

Specifications

Feed Material Hard, medium-hard, soft, brittle, elastic, fibrous
Material Feed Size ≤ 8 mm
Feed Quantity Max. 2 × 20 ml
Size Reduction Principle Impact, friction
Final Fineness About 3µm
Number of Grinding Stations Two
Frequency of Vibration/ Range of Spindle Speed 60 to 2400 rpm
Setting of Vibrational Frequency 60 to 1800rpm / 30 Hz
Typical Mean Grinding Time 3 to 5 min
Cell Disruption with Reaction Vials Up to 20 × 2.00 ml
Type of Grinding Jars Screw top design
Material of Grinding Tools Hardened steel, stainless steel, tungsten carbide, agate, zirconium oxide,
Grinding Jar Size Available 0.2 ml, 1.2 ml, 1.5 ml, 2.0 ml, 5.0 ml, 50 ml
Grinding Jar Volume 30 ml × 2 / 50 ml × 2
Digital Grinding Time Setting 10 sec to 99 min
Storage Memory 9 SOPs or more
Self-Centring Clamping Device Yes
Dry Grinding Yes
Wet Grinding Yes
Cryogenic Grinding Yes
Protection Code IP 30
Quality Standard CE Marked
Power Consumption 0.4 kW
Power Supply 220 volts, 50 Hz
Dimension 400 × 500 × 300 mm
Weight 30 Kg

Features

Easy operation

Rapid grinding

Multi sample handling

Lossless wet grinding

FAQs

1. What are the key factors to consider when selecting this tissue grinder for laboratory use?

When selecting this tissue grinder, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this tissue grinder be calibrated to ensure accurate results?

It is recommended to calibrate this tissue grinder at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this tissue grinder?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this tissue grinder be used with different types of samples, and are there any compatibility considerations?

Yes, this tissue grinder can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the tissue grinder malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.