Introduction

Multi Parameter Water Quality Analyzer delivers consistent performance with a repeatability of 3%. It can detect , ammonia, nitrogen and phosphorus levels simultaneously with high precision. With 0 to 3.5Abs absorbance detection range, this unit accommodates various sample concentrations. A durable light source ensures long term operation and reliability. Ideal for environmental monitoring and wastewater assessment, our Water Quality Analyzer is versatile and used across diverse industries.

This water testing equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Our Multi Parameter Water Quality Analyzer monitors chlorine, , nitrogen and phosphorus content in water samples from wastewater treatment plants, water purification plants, pharmaceutical industries and agricultural sectors to ensure water quality.

Specifications

Indication Error ≤±5%
Repeatability 3%
Detection Method Potassium dichromate method
Potassium permanganate method
Measuring Range 10 to 15000 mg/L
Test Limit 3mg/L
Digestion Temperature 165℃, 20min
Indication Error ≤±5% or ± 4mg/L
Repeatability ≤3%
Ammonia Nitrogen Detection Method Salicylic acid method
Nesslers reagent method
Ammonia Nitrogen Measuring Range 0.02 to 100 mg/L
Ammonia Nitrogen Test Limit 0.005 mg/L
Ammonia Nitrogen Digestion Temperature N/A
Ammonia Nitrogen Indication Error ≤±5% or ±0.1 mg/L
Ammonia Nitrogen Repeatability ≤3%
Total Phosphorus Detection Method Ammonium molybdate method
Total Phosphorus Measuring Range 0.02 to 20mg/L
Total Phosphorus Test Limit 0.0005mg/L
Total Phosphorus Digestion Temperature 150℃, 15min
Total Phosphorus Indication Error ≤±5% or ±0.04 mg/L
Total Phosphorus Repeatability ≤3%
Total Nitrogen Detection Method Thymol method
Total Nitrogen Measuring Range 0.5 to 500 mg/L
Total Nitrogen Test Limit 0.25 mg/L
Total Nitrogen Digestion Temperature 125℃, 30 min
Total Nitrogen Indication Error ≤±5% or ±0.4mg/L
Total Nitrogen Repeatability ≤3%
Absorbance Detection Range 0 to 3.5Abs
Optical Path Stability ≤±0.002 Abs/30min
Absorbance Resolution 0.001 Abs
Operation Repeatability ≤±0.005 Abs
Light Source Life 100,000 hours
Filter Life 5 years
Operating Temperature 0 to 50℃
Operating Humidity 0 to 90%
Data Storage 10000 pcs
Power Supply DC 12V/5A
Dimension (L×W×H) 412×253×164 mm
Weight 3.25 kg

Features

light source

7-inch touchscreen

Intelligent detection system

Printer connection available

Safe operation

FAQs

1. What are the key factors to consider when selecting this water testing equipment for laboratory use?

When selecting this water testing equipment, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this water testing equipment be calibrated to ensure accurate results?

It is recommended to calibrate this water testing equipment at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this water testing equipment?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this water testing equipment be used with different types of samples, and are there any compatibility considerations?

Yes, this water testing equipment can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the water testing equipment malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.