Introduction

Halogen Moisture Analyzer supports a maximum weighing capacity of 210g and comes with a high-quality load cell for accurate measurements. It is equipped with advanced a 7-inch high-definition touch display that provides real-time dynamic analysis. Incorporates a halogen lamp heat source and a PT 100 temperature sensor for consistent and efficient drying. Our analyzer is designed for fast updates and upgrades, keeping it up-to-date with the latest innovations. This analytical equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

The Halogen Moisture Analyzer is ideal for quick moisture content analysis in various industries, including pharmaceuticals, chemicals, and food processing.

Specifications

Capacity 210g
Readability 0.001g
Operating Temperature 5°C to 35°C
Pan Size Ø100mm
Heat Source Halogen Lamp
Temperature Sensor PT 100
Temperature Range 40°C to 230°C
Temperature Step 1°C
Moisture Range 0.00% to 100.00%
Moisture Readability 0.0001
Dry Residual Range 100.00% to 0.00%
Dry Residual Readability 0.0001
100% to 999%
(Alternate Range) 0% to 999%
Temperature Setting 40°C to 230°C by 1°C step
Time Setting 1 to 99min by 10s
Number of Storage Slots 20
Number of History Logs 20
Communication Mode Cable
Calibration External Calibration
Function Expansion Customized
Operation Height 275mm
Chamber Height 35mm
Display 7-inch touch panel
Interface RS232 / RJ45 /
Heater Voltage 220V ±15% 50Hz / 110V ±15% 60Hz
Heater Power 400W
Balance Input 220V 50Hz/110V 60Hz
Balance Output 9V
Machine Input 220V 50Hz/110V 60Hz
Machine Output 24V (Dual drive)
Indicator Dimension 200 × 75 × 135mm
Main Body Dimension 215 × 195 × 415mm
Weight 10 Kg

Features

Automatic heating cabin door with double drives

Ultra-quiet to avoid impact on the weight sensor

7-inch HD touch display for real-time analysis

Visual window for real-time sample monitoring

Four-layer stainless steel heating

Supports a variety of high-temperature materials

Patented design for appearance and structure

Open tray design for easy residue cleaning

Removable test cover for accessory replacement

Anti-pinch and automatic detection feature

FAQs

1. What are the key factors to consider when selecting this analytical equipment for laboratory use?

When selecting this analytical equipment, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this analytical equipment be calibrated to ensure accurate results?

It is recommended to calibrate this analytical equipment at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this analytical equipment?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this analytical equipment be used with different types of samples, and are there any compatibility considerations?

Yes, this analytical equipment can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the analytical equipment malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.