Introduction

Automated Kinematic Viscometer features an auto sampler of 12 positions for smooth and automated operation. It offers temperature control range of 20℃ to 100℃, supported by silicone fluid as the bath medium. This system incorporates a modified Ubbelohde viscometer for reliable performance across a wide viscosity range. Its data can be easily exported via RS232 ports to or a printer, enhancing laboratory efficiency. It operates efficiently under standard lab conditions, making it a reliable choice for petroleum, chemical, and research laboratories.

This petroleum testing is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Our Automated Kinematic Viscometer is ideal for testing lubricants, polymers, chemicals, and coatings, ensuring consistency and quality in production processes.

Specifications

Temperature Range 20℃ to 100℃ (for temperatures around ambient, an external chiller is required)
Temperature Accuracy ±0.01℃
Timing Accuracy 0.02s
Auto Sampler Capacity 12 positions
Sample Preheating Ambient to 95℃
Bath Capacity 2.5L
Bath Medium Silicone Fluid
Viscosity Range 0.5 to 10000 mm²/s (depending on viscometer tube selection)
Viscometer Type Modified Ubbelohde
Safety Features Prompt for lack of solvent
Bath over temperature protection
Liquid level protection
I/O Port RS232 * 2
Standards D445, D446, 3104, 3105, IP 71, GB/T 265, GB/T 30515
Data Export or Printer
Machine Power ≤1000W
Heater Power 600W
Operating Conditions 5℃ to 35℃
20 to 90% RH at 35℃, Non-condensing
Power Supply AC 220V±10 50/60Hz
Dimensions (W×D×H) 400mm × 510mm × 710mm
Weight 60Kg (including bath medium)

Features

Wide temperature range

Low solvent usage per cycle

Movable sample tray design

Sample preheating for viscosity

Calibration for temperature, tube

Real-time data recording

Silicone Fluid Bath

Modified Ubbelohde Viscometer

FAQs

1. How does the dual-solvent cleaning system benefit laboratory operations in the Automated Kinematic Viscometer ?

It Automated Kinematic Viscometer features a dual-solvent system that allows the use of two different solvents, one for dissolving residues and another for rinsing. This helps improve cleaning results when working with different types of fluids, especially high-viscosity or sticky samples. The system cleans the capillary tube automatically, reducing manual work between tests. It also helps save solvent and lowers overall operating costs for the lab.

2. What happens if the ambient temperature is lower than the test bath temperature in the Automated Kinematic Viscometer ?

The Automated Kinematic Viscometer may lose heat more quickly if the room is cooler than the set bath temperature, which can affect test accuracy. We recommend using an external chiller to keep the bath stable, especially if testing around 20°C. Keeping the lab temperature steady between 20–25°C helps the instrument perform correctly. The insulated bath design also helps limit heat loss during tests.

3. How do we troubleshoot inaccurate viscosity readings in the Automated Kinematic Viscometer ?

Automated Kinematic Viscometer may give inaccurate readings due to calibration issues, buildup inside the capillary tube, sensor problems, or unstable temperature. To fix this, check calibration using a certified standard fluid, and clean or replace the tube if needed. Also check the meniscus sensor and bath fluid condition. Make sure there are no bubbles in the sample and that leftover solvent is not affecting flow. Regular maintenance helps avoid these problems.

4. How can we reduce solvent consumption in Automated Kinematic Viscometer during the testing and cleaning process?

The Automated Kinematic Viscometer allows you to lower solvent use by adjusting cleaning settings such as rinse time and number of cleaning cycles. Use the drying feature after each test to remove residue and avoid repeat rinsing. Choose solvents that match the sample type to avoid wasting extra solvent. Clean samples and filter out debris before testing to keep the system efficient.

5. What should we do if the meniscus is not detected properly in Automated Kinematic Viscometer ?

Automated Kinematic Viscometer may fail to detect the meniscus if the sample is cloudy, contains bubbles, or the sensor is not aligned. Make sure the capillary tube is clean and securely placed. Check for bubbles or foam in the sample and remove them before starting. If the problem continues, run a system check or contact support to adjust or recalibrate the sensor.

6. What precautions should we take while handling solvents and samples in Automated Kinematic Viscometer ?

Automated Kinematic Viscometer should be used with care when handling solvents and test fluids. Always work in a well-ventilated area and wear safety gloves and goggles. Store solvents in proper containers and make sure waste is collected in the attached disposal system. Keep all tools and sample containers clean to avoid contamination and protect the user.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.