Introduction
Portable Dissolved Oxygen Tester supports up to 12 parameters: pH, EC, , DO, Temperature, mV, , pX, Resistivity, , Salinity, and DO Saturation. It is equipped with advanced a 4.3-inch high-contrast touchscreen for easy parameter setting. The intelligent system includes user, calibration, electrode methods, and data management. The automatic and manual temperature compensation ensures highly accurate readings in diverse environmental conditions. This dissolved oxygen meter is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
The Portable Dissolved Oxygen Tester is ideal for water quality testing in environmental monitoring, aquaculture, wastewater treatment, and laboratory research. Its precision, multi-mode readings, and rugged IP65 waterproof design make it perfect for both fieldwork and lab use.Specifications
| pH Range | -2.000 to 20.000 pH |
| pH Resolution | 0.1, 0.01, 0.001 pH |
| pH Accuracy | ±0.002 pH |
| pH Calibration Points | Up to 8 |
| pH Standard Customization | Yes |
| pH Standard Recognition | , , , , GB and buffers |
| pH Calibration Reminder | Yes |
| pH Slope Limit | Yes |
| Selectable Pressure Units | kPa, mbar, Torr, Atm |
| mV/ Range | -2000.00 to 2000.00 mV |
| mV/ Resolution | 0.1, 0.01 mV |
| mV/ Accuracy | ±0.1 mV or ±0.3% of reading (whichever is greater) |
| EH Mode | Yes |
| Calibration Points | 1 custom point (relative mV) |
| pX Range | -2.000 to 20.000 pX |
| pX Resolution | 0.1, 0.01, 0.001 pX |
| pX Accuracy | ±0.002 pX |
| pX Calibration Points | Up to 6 |
| (Ion Selective Electrode) Range | 1E-9 to 9.999E5 |
| Units | mol/L, mmol/L, g/L, mg/L, µg/L |
| Resolution | Up to 4 significant digits |
| Calibration Points | Up to 8 |
| Conductivity Range | 0.000 μS/cm to 500.000 mS/cm |
| Conductivity Resolution | 0.001 μS/cm minimum (changes with range) |
| Conductivity Accuracy | ±0.5% FS |
| Reference Temperature | 5, 10, 15, 18, 20, 25 °C |
| Conductivity Calibration Points | Up to 5 |
| Conductivity Calibration Reminder | Yes |
| Conductivity Standard Recognition | 10 μS/cm, 84 μS/cm, 500 μS/cm, 1413 μS/cm, 12.88 mS/cm |
| Resistivity Range | 5.000Ω·cm to ~100.0MΩ·cm |
| Resistivity Resolution | 0.010Ω·cm minimum |
| Resistivity Accuracy | ±0.5% FS |
| (Total Dissolved Solids) Range | 0.000mg/L to ~100g/L |
| Resolution | 0.001mg/L minimum (changes with range) |
| Accuracy | ±0.5% |
| Salinity Range | 0.00 to 8.00% |
| Salinity Resolution | 0.0001 |
| Salinity Accuracy | ±0.1% |
| Salinity Sensor Type | Polarographic |
| Dissolved Oxygen Concentration Range | 0.00 to 99.99 mg/L |
| Resolution | 0.01mg/L |
| Accuracy | ±0.3mg/L (0.00 to 20.00mg/L), ±10% (20.00 to 99.99mg/L) |
| Calibration Reminder | Yes |
| Calibration Points | Air-saturated water or zero point |
| Barometric Compensation | Yes |
| Manual Salinity Factor Correction | Yes |
| Saturation Range | 0.0% to 600.0% |
| Saturation Resolution | 0.001 |
| Saturation Accuracy | ±10% |
| Temperature Range | -10 to 135°C, 14 to 275°F |
| Temperature Resolution | °C, °F |
| Temperature Relative Accuracy | ±0.2 |
| Reading Mode | Auto Read (Fast, Medium, Slow), Timed, Continuous |
| Reading Prompts | Reading, Stable, Locked |
| Data Storage | 1000 Groups |
| Features | Yes |
| pH Electrode | /Q9 |
| Temp./DO Probe | 4-pin aviation connector |
| Temp./EC Probe | 5-pin aviation connector |
| Type | 2.0 flash memory device, PC, scanner |
| Bluetooth | Yes |
| Backlight | Yes |
| Auto Shutdown | 300, 600, 1200, 1800, 3600 seconds; off |
| IP Rating | IP65 |
| Date and Time | Yes |
| Power | Rechargeable Lithium battery; AC Adapter |
| Adapter | 100-240V AC input, DC5V output |
| Dimensions | 90 × 255 × 44 mm |
| Weight | 0.5 Kg |
Features
communication supported
Auto power-off for extended battery life
Reset feature restores factory settings
IP65 waterproof for outdoor use
Supports air-saturated water
Supports zero oxygen calibration
Barometric pressure compensation
Manual salinity factor correction
FAQs
1. What are the key factors to consider when selecting this dissolved oxygen meter for laboratory use?
When selecting this dissolved oxygen meter, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.
2. How often should this dissolved oxygen meter be calibrated to ensure accurate results?
It is recommended to calibrate this dissolved oxygen meter at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.
3. What are the common maintenance procedures required for this dissolved oxygen meter?
Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.
4. Can this dissolved oxygen meter be used with different types of samples, and are there any compatibility considerations?
Yes, this dissolved oxygen meter can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.
5. What should be done if the dissolved oxygen meter malfunctions or produces inconsistent results?
If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.