Introduction

Refrigerated Centrifuge rotates with a maximum speed of 8000 rpm with a relative centrifugal force of up to 14550 × g. It features a brushless frequency motor with high torque that requires no maintenance. It provides fast acceleration and deceleration and prevents powder pollution. It is equipped with advanced a 7-inch touchscreen that displays the program, speed, time, , and temperature. Our refrigerated centrifuge is CE and certified, with available calibration reports for safety standards.

It utilizes high-speed rotation to separate components of different densities, widely used in biological, medical, and chemical laboratories. The unit is equipped with safety protection systems to ensure operator safety during high-speed operation.

Applications

Refrigerated Centrifuge is a high-performance centrifuge designed for large-capacity applications, ideal for blood banks, pharmaceutical factories, and laboratories.

Specifications

Max. Speed 8000 rpm
Max. 14550 × g
Max. Capacity 8 × 2000 ml
Blood Bag Capacity 16 × 500 ml blood bag
Time Range 1 to 99h 59min 59s
/ Convert Yes
Noise ≤ 65 dB
Acceleration/Deceleration 10
Temperature Range -20 to 40 ℃
Speed Accuracy 10 kinds
Temperature Accuracy ± 20 r/min
Data Storage ± 1 ℃
Certificates 100 programs
Power Supply CE, & Calibration report available
Dimensions (L × W × H) AC 220V / 380V 50Hz / 60Hz
Packaging Dimensions (L × W × H) 940 × 890 × 1000 mm
Net Weight 1200 × 1050 × 1570 mm
Gross Weight 570 Kg

Features

Micro-computer control mode

Acceleration and deceleration options

Electric lid lock for safety

Made of high-quality steel

Compact design and easy operation

Protection against overspeed and imbalance

FAQs

1. What is the maximum sample volume that can be processed in the centrifuge?

The maximum sample volume depends on the type of rotor used with the centrifuge. Typical rotors can accommodate sample volumes ranging from 0.2 mL (microcentrifuge tubes) to 50 mL (conical tubes) or larger for specialized rotors. It is important to check the centrifuge's specifications and rotor compatibility to ensure that the sample volume does not exceed the recommended limits, which could affect centrifugation efficiency and safety.

2. How to balance the centrifuge before operation?

Proper balancing is critical for safe and effective centrifuge operation: 1) Ensure that all sample tubes have the same volume and weight; 2) Place the tubes symmetrically in the rotor, opposite each other; 3) For odd numbers of samples, use a balance tube filled with the same volume of appropriate solution; 4) Check that the rotor is properly seated and secured in the centrifuge; 5) Avoid overloading the rotor beyond its maximum capacity.

3. What is the difference between relative centrifugal force (RCF) and revolutions per minute (RPM)?

RCF is a measure of the centrifugal force applied to the sample, expressed in multiples of gravity (x g), and depends on both the RPM and the radius of the rotor. RPM is a measure of the rotor's rotation speed in revolutions per minute. The relationship between RCF and RPM is given by the formula: RCF = 1.118 × 10^-5 × r × RPM² (where r is the rotor radius in centimeters). For most applications, RCF is the preferred parameter as it directly relates to the separation efficiency, regardless of rotor size.

4. How to maintain the centrifuge to ensure long service life?

Regular maintenance includes: 1) Cleaning the rotor and chamber after each use to remove sample spills and debris; 2) Inspecting the rotor for cracks, corrosion, or wear before each use; 3) Lubricating moving parts according to the manufacturer's recommendations; 4) Calibrating the speed and temperature controls annually or after major service; 5) Ensuring proper ventilation around the centrifuge to prevent overheating; 6) Storing the centrifuge in a clean, dry environment when not in use.

5. What safety precautions should be taken when using the centrifuge?

Important safety precautions include: 1) Always balance the sample tubes properly before operation; 2) Ensure the rotor is correctly installed and secured; 3) Do not open the centrifuge lid while the rotor is still spinning; 4) Use appropriate personal protective equipment (gloves, goggles) when handling samples and cleaning the equipment; 5) Avoid overloading the centrifuge beyond its maximum capacity; 6) Regularly inspect the centrifuge for any signs of damage or malfunction and discontinue use if any issues are found.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.