Introduction
Vertical Autoclave has a chamber capacity of 100 liters and is powered by a robust 4.5 kW heating system. It is equipped with advanced microcomputer automatic control, for arbitrary sterilization parameter settings. It features a handwheel translation and quick-opening structure, along with a three-times pre-vacuum system. The autoclave automatically discharges cold air and exhausts steam after sterilization, making it user-friendly and efficient. It uses high-temperature and high-pressure steam to achieve effective sterilization of laboratory equipment, media, and waste. The advanced control system ensures thorough sterilization while preventing overheating or pressure buildup.Applications
Our Vertical Autoclave is a high-performance sterilization unit designed for laboratories, medical facilities, and research institutions.Specifications
| Capacity | 100L |
| Design Pressure | 0.25Mpa |
| Design Temperature | 139°C |
| Rated Working Pressure | 0.22Mpa |
| Rated Working Temperature | 134°C |
| Sterilization Temperature | 116°C to 134°C |
| Temperature Accuracy | ±1°C |
| Sterilization Time Setting Range | 4 to 120 min |
| Drying Time Setting Range | 0 to 240 min |
| Chamber Volume | Ø450×650 |
| Bucket Dimension | Ø420×540 |
| Basket Dimension (Optional) | Ø410×300×2 |
| Protection Function | Over-Temperature Protection, Overpressure Self-Discharge Protection, Low Water Level Protection, And Anti-Dry Burning Safeguards. |
| Basket Material | Stainless steel |
| Power Consumption | 4.5kW |
| Power Supply | AC 220V, 50HZ |
| External Dimension (W×D×H) | 760×560×1260 mm |
| Package Dimension (W×D×H) | 870×660×1400 mm |
| Net Weight | 132 Kg |
| Gross Weight | 146 Kg |
Features
High-quality stainless-steel body
Interlocking device for safety
touchscreen display
Standard test interface
Self-expanding seal
Built-in Printer and port
Automatic stop function
Post-sterilization buzzer reminder
Drying and automatic protection function
FAQs
1. What is the recommended sterilization cycle for different types of laboratory materials?
The recommended cycle depends on the material type: 1) For glassware and heat-resistant materials: 121°C, 15-20 psi, for 15-20 minutes; 2) For liquid media: 121°C, 15-20 psi, for 20-30 minutes (longer for larger volumes); 3) For wrapped instruments: 121°C, 15-20 psi, for 25-30 minutes to ensure steam penetration; 4) For waste materials: 132°C, 30 psi, for 30 minutes for biohazardous waste; 5) For heat-sensitive materials: Use a lower temperature (115°C) for a longer duration (30 minutes) or a specialized cycle if available. Always refer to the material manufacturer's recommendations.
2. How to properly load the autoclave to ensure effective sterilization?
Proper loading is crucial: 1) Place items in a way that allows steam to circulate freely around all surfaces; 2) Avoid overloading the autoclave chamber, leaving at least 2-3 inches of space between items; 3) Stack items with openings facing downward to prevent water accumulation and ensure steam penetration; 4) Use autoclave-compatible containers and avoid sealing them tightly (leave lids loose or use vented caps); 5) Separate different types of materials if possible, especially liquids and solids; 6) Ensure that liquid containers are not filled more than 2/3 full to prevent boiling over.
3. What maintenance procedures are required for the autoclave?
Regular maintenance includes: 1) Draining and cleaning the water reservoir after each use to prevent mineral buildup; 2) Descaling the autoclave monthly (or more frequently in hard water areas) using a recommended descaling agent; 3) Inspecting the door gasket for wear, cracks, or damage and replacing it if necessary; 4) Checking the pressure relief valve and safety interlocks quarterly to ensure proper operation; 5) Cleaning the chamber interior with a mild detergent after each use; 6) Performing annual calibration of temperature and pressure gauges by qualified personnel; 7) Keeping a maintenance log to track all service activities.
4. How to troubleshoot if the autoclave fails to reach the desired temperature or pressure?
If temperature/pressure issues occur: 1) Check if the water level in the reservoir is sufficient; 2) Verify that the door is properly closed and sealed (check gasket for damage); 3) Inspect the heating element for signs of malfunction; 4) Check the pressure relief valve to ensure it is not stuck open; 5) Clean the steam vents and drains to remove any blockages; 6) Ensure the autoclave is properly grounded and the power supply is stable; 7) If the problem persists, do not use the autoclave and contact technical support immediately, as it may pose a safety risk.
5. What safety precautions should be followed when operating the autoclave?
Important safety precautions: 1) Never open the autoclave door while it is pressurized or during the sterilization cycle; 2) Allow the autoclave to cool down and depressurize completely before opening; 3) Wear heat-resistant gloves and eye protection when handling hot items; 4) Stand to the side of the autoclave when opening the door to avoid steam burns; 5) Never autoclave incompatible materials (such as volatile solvents, oils, or explosives); 6) Regularly test the autoclave's performance using biological indicators (spore tests) to ensure effective sterilization; 7) Familiarize yourself with the emergency stop procedures and location of safety devices.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.