Introduction

The features a chamber volume of 126L and operates at a washing temperature range of 50-93℃ for efficient cleaning. It supports 35 default programs and 100 user-defined settings, making it suitable for various laboratory needs. The washer includes multi-level password protection to ensure secure access. It comes with an automatic opening door with a viewing window for easy monitoring. Our glassware washer is ideal for cleaning and drying applications in laboratories, ensuring efficient and reliable performance. This glassware washer is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Glassware washer is commonly used in research laboratories, pharmaceutical industries, and food processing. It is used for cleaning and drying items such as Erlenmeyer flasks, volumetric flasks, pipettes, injection vials, petri dishes, and more.

Specifications

Chamber Volume 126L
Material Inner Chamber 316L/Shell 304
Programs 35 default, 100 user-defined
Circulation Pump Flow Rate 320L/min
Washing Temperature 50-93℃
Number of Cleaning Layers 1
Number of Peristaltic Pump 2
Condensing Unit Yes
Module Yes
RS232 Printing Interface Yes
Total Power 8kw/13kw
Heating Power 4kw/9kw
Drying Power 2kw
Power Supply 220V/380V
Weight 100 kg
Dimension (W × D × H) 612 × 750 × 685 mm
Inner Cavity Dimension (W × D × H) 540 × 550 × 402 mm

Features

Modular baskets, two per layer

Waterproof display

Microcomputer intelligent control

Stainless steel buttons with 3 shortcut keys

Conductivity detection function

Data storage function

Wash start delay and shutdown delay functions

FAQs

1. What are the key factors to consider when selecting this glassware washer for laboratory use?

When selecting this glassware washer, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this glassware washer be calibrated to ensure accurate results?

It is recommended to calibrate this glassware washer at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this glassware washer?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this glassware washer be used with different types of samples, and are there any compatibility considerations?

Yes, this glassware washer can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the glassware washer malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.