The Planetary Mixer is a high-performance, touch-screen mixer with an adjustable dispersion speed of 1450 rpm. It has a single direct material temperature measurement mode that enhances efficiency. The barrel has a 10L design volume and is 5L effective, made from SUS304 stainless steel. The vacuum system can maintain a vacuum degree of ≤-0.95Mpa, ensuring no oil leakage. Our mixer provide thorough mixing through strong kneading motions. This laboratory mixers is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Our planetary mixer is ideal for thorough and precise mixing in industrial and laboratory settings.Specifications
| Barrel Body Volume | Design Volume: 10L Effective Volume: 5L |
| Barrel Body Material | SUS304 Mirror-polished |
| Cooling/Heating | G1/2" water inlet/outlet Jacket for cold/hot water or oil |
| Upper Barrel | SUS304 Feeding hopper 1 spotlight 2 windows Vacuum port |
| Mixing Principle | Low-gap double paddles, strong kneading |
| Revolution Motor | Power: 1.5KW Frequency converter Reducer ratio: I = 40.26 |
| Planetary Revolution Speed | 0 to 48 rpm, adjustable |
| Scraper | SUS304 and Teflon |
| Clearance Reference Value | Paddle to paddle: 10±2.5mm Paddle to bottom: 2 to 6mm Slurry to wall: 5±1.5mm |
| Stirring Paddle | Material: SUS304 Quantity: 2 |
| Stirring Paddle Speed | 0 to 86rpm, adjustable |
| Decentralized Motor | 1.5KW |
| Dispersion Speed | 1450 rpm |
| Dispersing Disc Diameter | 60mm |
| Lift (Pot Body) | Electric Linear guide rail Motor: 0.18KW |
| Vacuum System | ≤-0.95Mpa Mechanical and O-ring seals Pressure maintained for 12 hours |
| Control Panel | Controls vacuum, speed, temperature, spotlight, lift, emergency stop |
| Safety Features | Auto-stop upper barrel, prevents operation during lifting, Vacuum buffer tank |
| Temperature Measurement | 0 to 30℃ Probe near bottom |
| Power Consumption | 4.2KW |
| Power Supply | 380V/50Hz/3Phase Control: 220V |
| Dimension | 1300 × 1100 × 700 mm |
| Weight | 400 Kg |
Features
High-performance
Electric pot body lifting mechanism
Double stirring shaft
Stainless steel barrel
Mirror-polished inner tank
Automatic stops and interlocks
Special vacuum buffer tank design
FAQs
1. What are the key factors to consider when selecting this laboratory mixers for laboratory use?
When selecting this laboratory mixers, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.
2. How often should this laboratory mixers be calibrated to ensure accurate results?
It is recommended to calibrate this laboratory mixers at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.
3. What are the common maintenance procedures required for this laboratory mixers?
Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.
4. Can this laboratory mixers be used with different types of samples, and are there any compatibility considerations?
Yes, this laboratory mixers can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.
5. What should be done if the laboratory mixers malfunctions or produces inconsistent results?
If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.