Introduction

Real Time can scan 96 samples across 6 fluorescent channels within 5 seconds. It features a strong fluorescence signal with low background noise and high sensitivity. The long-lasting, and maintenance-free. The PC operation function of this allows one computer to control multiple instruments. Our ’s powerful software analysis functions support both qualitative and quantitative analysis. This analytical equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Our Real Time applies to scientific research, clinical diagnosis, animal husbandry agriculture, pet hospitals, food safety, in vitro diagnosis, and more.

Specifications

Sample Capacity 96 well, 12 ×8 strip, 96 × 0.2ml single tube
Consumable 0.1/0.2ml tube, 0.2ml 8-tube strips, 0.2ml 96 well plate
Reaction Volume Range 10 to 100μl
Temperature Range 0 to 105°C
Temperature Resolution 0.1°C
Max. Ramp Rate 8.0°C/s
Temperature Control Accuracy ±0.1°C
Uniformity ±0.20°C
Accuracy ±0.20°C
Gradient Speed 0.1 to 42°C
Hot Lid Temperature 30 to 110°C (Adjustable, default 105°C)
Lid Operation Automatic hot lid
Temperature Control Block/Tube
Excitation Wavelength 300nm to 810nm
Emission Wavelength 500 nm to 810 nm
Detection Channel 6 Channel
Scan Period 5 seconds to complete 96 well test
Factory Calibrated Dyes F1: /-Green/-Green
F2: ////
F3: /Texas Red
F4: Cy5
F5:Cy5.5
F6: CY3(customized)
Excitation Long life
Detection High-sensitivity photoelectric detector
Dynamic Range 1-10¹⁰ Copies
Sensitivity 1 copy
Feature Function Qualitative/absolute quantification, relative quantitative, genotyping, , melting curve, standard curve, allele identification, temperature gradient function, etc.
Remote Monitoring can connected to a laboratory management system
Automation Platform Can be used with automated workstations
Data Export Formats excel, , txt, pdf
Printing Direct printing of reports
Display 12-inch color touchscreen
Control Method Connectable to the computer control
Communication USB2.0, RS232
Power 1400W
Power Supply 100-240VAC 50-60Hz
Dimension (L × W × H) 495 × 350 × 330 mm
Weight 28 Kg

Features

Equipped with automatic hot lid

Simultaneous channels scanning

High-sensitivity photoelectric detector

12-inch color touchscreen

Printer for record printing

communication port

FAQs

1. What are the key factors to consider when selecting this analytical equipment for laboratory use?

When selecting this analytical equipment, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this analytical equipment be calibrated to ensure accurate results?

It is recommended to calibrate this analytical equipment at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this analytical equipment?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this analytical equipment be used with different types of samples, and are there any compatibility considerations?

Yes, this analytical equipment can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the analytical equipment malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.