Introduction
Electronic Wood Density Meter is robust and compact design device. It offers 0 .001 to 150 g weighing range and 10 seconds testing time. Designed with wood products, density and volume of the products can be showed direct. It is used in Boiling method, vacuum saturation method and applied for testing the basic density, bulk , wet, apparent density, apparent porosity, water absorption, volume of open pores and closed pores, total porosity of wood For testing air-dried density of wood in laboratory and production environments. This density meter is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Electronic Wood Density Meter used for testing the basic density, bulk ,wet, apparent density, apparent porosity, water absorption, volume of open pores and closed pores, total porosity of wood for testing air-dried density of wood, the bulk density also used across wax-sealing method for non-absorbent wood products.Specifications
| Weighing range | 0 .001 to 150 g |
| Minimum sample weight | 5 g |
| Maximum weighing capacity | 150 g |
| Water absorption and porosity | 0.0001 |
| Density resolution | 0.001g/cm3 |
| Built-in weighing sensor | German |
| A cage for floating objects | Yes |
| Function of solution compensation | Yes |
| Either water or liquid can be used as medium | Yes |
| Rechargeable batteries | NA |
| Wind-proof outer cover | Yes |
| Standard interface | |
| Testing time | 10 seconds |
| Temperature range | 0 to 40℃ |
| Display | Digital Screen Display |
| Dimension | 195 × 210 × 185 mm |
| Packing dimension | 395 × 195 × 330 mm |
| Power supply | AC 220 V, 50 Hz |
| Net weight | 3.5 kg |
| Gross weight | 4.5 kg |
Features
Designed with digital Screen display to observe density, volume, water absorption and porosity
Built-in temperature compensation function, ranges from 0 to 40℃
Offers easy to navigate user interface and intuitive operation
Intelligent data processor can store measurement data (Optional)
Robust components ensure a long device for lifetime and with space-saving design
Equipped for non-absorbent wood products, density and volume of the products can be showed direct
Designed with wax-sealing method for porous material
Fast and precise testing
Offers direct reading
User-Friendly and safe operations
It is used in laboratory and production environments
FAQs
1. What are the key factors to consider when selecting this density meter for laboratory use?
When selecting this density meter, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.
2. How often should this density meter be calibrated to ensure accurate results?
It is recommended to calibrate this density meter at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.
3. What are the common maintenance procedures required for this density meter?
Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.
4. Can this density meter be used with different types of samples, and are there any compatibility considerations?
Yes, this density meter can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.
5. What should be done if the density meter malfunctions or produces inconsistent results?
If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

