Introduction
Xenon Test Chamber is a spacious 408L chamber that works in a temperature range of 10℃ to 80℃. It utilizes an imported air-cooled full solar spectrum long arc xenon lamp as the light source. A water spray function is available to simulate the effects of outdoor moisture on materials. Our test chamber Integrates a high-quality xenon arc tube for consistent performance. Offers quick and easy lamp replacement with durable filters to maintain the required spectrum. This test equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Our Xenon Test Chamber is suitable for tests such as selecting new materials, improving existing materials, or evaluating changes in durability due to material composition changes. Applicable materials include plastics, rubber, paints, ink, paper, pharmaceuticals, food, cosmetics, textiles, auto parts, packaging materials, construction materials, and electrical products.Specifications
| Capacity | 408L |
| Temperature range | 10℃ to 80℃ |
| Temperature deviation | ± 2℃ |
| Humidity range | 65 to 98%R.H |
| Display | 5.7-inch screen |
| Humidity deviation | group: 3 zones Deviation : 1 Zone |
| Storage Program | 120 Group / 1200 segment |
| Control | ± 2.5%R.H (humidity ≥ 75%R.H) ±3%R.H (humidity ≤ 75%R.H) |
| Input Control | Universal input 1 point, 0.1% of FS |
| Output Control | 2 points (heating, cooling) |
| Light source wavelength range | 290 to 800nm |
| xenon lamp service life | 1500 hours |
| Xenon lamp quantity | 2 pieces |
| Xenon lamp power | 1.8KW |
| Rain time | 1 to 9999 minutes |
| Rain cycle | 1 to 240 minutes |
| Spectral wavelength | 290nm to 800nm |
| Heating power | 4.6KW |
| Humidification power | 3KW |
| Light source irradiance | Full spectrum 100 to 800w/m² |
| Irradiation area | 5500cm² |
| arc center to sample holder Distance | 35 to 380mm |
| Water spray time | 0 to 9999h |
| Stop spraying time | 0 to 9999h |
| Blackboard temperature | 63℃ to 100℃ (deviation±3℃) |
| Environmental temperature | 26 ℃ |
| Environmental humidity | ≤ 85% R.H |
| Cooling method | Mechanical cooling and air cooling |
| Total power | about 8.5KW |
| power supply | 380V±10% 50HZ |
| Inner Dimension (D×W×H) | 800 × 600 × 850 mm |
| Exterior Dimension (W×D×H) | 1350 × 1200 × 1850mm |
| Weight | 350 Kg |
Features
Illumination time can be programmed continuously
Multiple Filter Systems Available
Relative Humidity Control function
Air Temperature Control System
Irregularly Shaped Sample Holder
Minimal routine maintenance required
FAQs
1. What are the key factors to consider when selecting this test equipment for laboratory use?
When selecting this test equipment, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.
2. How often should this test equipment be calibrated to ensure accurate results?
It is recommended to calibrate this test equipment at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.
3. What are the common maintenance procedures required for this test equipment?
Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.
4. Can this test equipment be used with different types of samples, and are there any compatibility considerations?
Yes, this test equipment can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.
5. What should be done if the test equipment malfunctions or produces inconsistent results?
If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.