Introduction
Ion chromatograph system offers a pump flow rate of 0.001 to 9.999mL/min with an eluent flow rate of 0.1 to 5.0mL/min. It features a built-in eluent generator for equal or gradient elution. Capable of performing suppression or non-suppression conductivity detection. The software features a baseline deduction function and filtering algorithm to effectively eliminate baseline drift. Our system is intelligent, stable, and accurate in performance.
This analytical equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Our ion chromatograph system can be used to detect fluoride and chloride in coal tar, ammonium in photoresists, bromate and bromide in drinking water, anions in engine coolants, lithium battery electrolytes, etc.
Specifications
| Generator Eluent Types | /NaOH/LiOH/ |
| Eluent Concentration Range | 0.1 to 100mM |
| Eluent Concentration Increment | 0.1mM |
| Eluent Flow Rate | 0.1 to 5.0mL/min |
| Maximum Pressure | 30MPa |
| Minimum Pressure | 5MPa |
| Accuracy Of Gradient | 0.0015 |
| Vacuum Degasser Degree | -70kPa |
| Degasser Internal Volume | 300μL |
| Degasser Maximum Flow Rate | 10mL/min |
| Degassing Efficiency | 1.0mL/min 90% |
| Degassing Volume | 7.5mL |
| Alarm system | Pressure Alarm, Liquid Leakage Alarm, and Washing Liquid Alarm |
| Flow Path | Chemically inert, metal-free flow paths |
| Pump Type | High-pressure and low-pulse two-piston tandem advection pump |
| Pump Maximum Pressure | 42MPa |
| Pump Flow Rate | 0.001 to 9.999mL/min |
| Pump Pressure Ripple | ≤ 0.5% |
| Pump Flow Precision | ≤ 0.1% |
| Pump Flow Accuracy | ≤ 0.1% |
| External Diameter of The Tube | 1/16 |
| Valve Control Mode | Stepper Motor |
| Valve Power Supply | 24V (DC) |
| Column Heater Temperature Range | Ambient + 5 to 60 ℃ |
| Column Heater Temperature Accuracy | ±0.1℃ |
| Temperature Stability | ≤ 0.05℃/h |
| Columns Supported | 2, 3, 4, and 5 mm I.D. |
| Analytical Column Size | 250 mm |
| Guard Column Size | 50 mm |
| Conductivity Detector Type | Auto-range conductivity |
| Conductivity Detector Cell Volume | ≤ 0.8μL |
| Conductivity Detection Range | 0 to 50000μS/cm |
| Conductivity Detector Resolution | ≤ 0.0020nS/cm |
| Detector Output Voltage | -6000 to +6000mv(adjustable) |
| Detector Electronic Noise | 0.02nS |
| Detector Baseline Noise | ≤ 0.0002μS/cm |
| Detector Baseline Drift | ≤ 0.001μS |
| Detector Temperature Range | Ambient +5℃ to 60℃ |
| Detector Temperature Accuracy | ±0.01℃ |
| Detector Temperature Compensation | 1.7 %/℃ |
| Detector Maximum Pressure | 10.0MPa |
| Detector Instrument Linearity | ≥ 0.999 |
| Detector Quantitative Repeatability | ≤ 0.2% |
| Detector Qualitative Repeatability | ≤ 0.5% |
| Minimum Detectability Concentration | Clˉ ≤ 0.0001ug/mL Li⁺ ≤ 0.0001ug/mL |
| Suppressor Type | Self-Regeneration electrolytic micro-membrane suppressor |
| Suppressor Maximum Pressure | 6.0MPa |
| Non-Suppressed Chromatography | Yes/support |
| Suppressor Void Volume | <40μL (4mm) <15μL (2mm) |
| Suppressor Power Supply | 150W |
| External Dimension (W × L × H) | 360 × 500 × 560 mm |
| Net Weight | 26 Kg |
| Gross Weight | 32 Kg |
Features
Various alarms for protection against operational issues
Auto-range conductivity detector expands signal range
Gas-liquid separator for removing bubble impact
High-performance auto-sampler enhances injection control
Start-up and warm-up procedures can be pre-set
Vacuum degasser for testing stability
Real-time monitoring ensures timely consumable replacement
FAQs
1. What are the key factors to consider when selecting this analytical equipment for laboratory use?
When selecting this analytical equipment, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.
2. How often should this analytical equipment be calibrated to ensure accurate results?
It is recommended to calibrate this analytical equipment at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.
3. What are the common maintenance procedures required for this analytical equipment?
Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.
4. Can this analytical equipment be used with different types of samples, and are there any compatibility considerations?
Yes, this analytical equipment can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.
5. What should be done if the analytical equipment malfunctions or produces inconsistent results?
If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.