Introduction

Universal Testing Machine works on a speed range of 0.001 to 500mm/min with an effective stroke of 600 mm. Our machine’s capacities range from low-load forces to high-load such as 100N, 200N, 500N,1KN, 2KN, and 2.5KN. Different tests can be conducted by simply replacing the clip, making it convenient and quick. Equipped with a high-precision sensor for imported load. It features touch screen control with a built-in printer for ease of operation.

This test equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

The Universal Testing Machine () finds widespread application in quality control, inspection, physical testing, mechanics research, material development, and production environment.

Specifications

Maximum Capacity 100N, 200N, 500N,1KN, 2KN, 2.5KN
Stretch Speed 0.001 to 500mm/min
Effective stroke 600 mm
Test Method Principle
Test Force Range Full stroke 1% to 100%
Collection Frequency Up to 1000Hz.
Force Accuracy ≤±0.2% F· S
Sample Clamp Mode Manual, pneumatic clamp
Stop Mode Overload Stop, Emergency Stop Button, Specimen Damage Automatic Stop, Upper & Lower Limit Set Automatic Stop, Automatic Return Function
Protection Measures Beam’s upper and lower limit protective device
Clamps defend touch protective device
Displacement set up & load limit software protective device
Sensor overload protection
Sample load software protection
Overcurrent & overvoltage protection
Real-time monitor for main parts
Connection Pad, , or cell phone
Power Consumption 500W
Power Supply AC 220V 50/60HZ
Dimensions (W × D × H) 670 × 480 × 1440 mm
Weight 120kg

Features

Constructed from aluminum alloy for durability

Surface treated with high-temperature curing spray

Includes digital setting functionality

Features automatic positioning

Enables adaptation to various test methods

Incorporated with a high-speed 24-bit A/D converter

FAQs

1. What are the key factors to consider when selecting this test equipment for laboratory use?

When selecting this test equipment, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this test equipment be calibrated to ensure accurate results?

It is recommended to calibrate this test equipment at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this test equipment?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this test equipment be used with different types of samples, and are there any compatibility considerations?

Yes, this test equipment can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the test equipment malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.