Introduction
Automatic Potentiometric Titrator automates the titration process by precisely measuring the volume of the titrant with a pH range of 0 to 14. Includes pH electrode for titration with suitable connecting cable Allows storage of up to 100 user-defined methods and 10 shortcuts for streamlined operation. Offers automatic calculation using predefined formulas for efficiency. Capable of storing 200 titration data sets in compliance with standards. Features data analysis tools for convenient review, comparison, and recalculation of results. This potentiometric titrator is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Automatic Potentiometric Titrator is used in quality control in pharmaceuticals, food and beverage analysis, environmental monitoring, chemical process control, water treatment, research and development, petrochemical analysis, etc.Specifications
| pH Measuring Range | 0.000 to14.000 pH |
| mV Measuring Range | -1999.90 to 1999.90 mV |
| Temperature Range | -5.0 to 105.0 ℃ |
| Temperature Sensor | 2.25K Ω, |
| pH Resolution | 0.001pH |
| mV Resolution | 0.01mV |
| Temperature Resolution | 0.1 ℃ |
| pH Accuracy | ±0.01pH ±1 bit |
| mV Accuracy | ±0.03% |
| Temperature Accuracy | ±0.3℃ |
| Burette Volume Accuracy | 10mlburette: ±0.025ml 20mlburette: ±0.035ml |
| Filling Time | 18 sec |
| Titration Reproducibility | 0.002 |
| Electric Unit Reproducibility | ≤ 0.2mV |
| Electric Unit Stability | ±0.3 mV ±1 bit/3h |
| Controlling Titration Sensitivity | ±2mV |
| Working Environments Temperature | 5.0~35.0 ℃ |
| Relative Humidity | ≤ 80% |
| Storage | 200 titration data sets |
| Communication Interface | |
| Display | 7-inch vibrant touchscreen |
| Display Function | Titration Methods, Curves, And Results |
| Dynamic Equivalence-Point Titration () | Yes |
| Monotonic Equivalence-Point Titration () | Yes |
| Titration To Preset Endpoints with Automatic Conditioning () | Yes |
| Calibration With Automatic Buffer Recognition () | Yes |
| Operating System | User, Method, Electrode, Titrant, And Data Management |
| Power Supply | 220 ± 22V, 50±1Hz |
| Main Dimension | 340×400×400 mm |
| Auxiliary Dimension | 200×110×230 mm |
| Weight | 10 Kg |
Features
Built-in magnetic stirrer
7-inch vibrant touchscreen with smart guide system
Additional burette driver
Replaceable high-accuracy burette
Intelligent operating system
Enables pH calibration and measurement functionalities
Data transfer to printers via
Computer control options via
Supports automatic sampler integration
Adopts transmission system and stirring system
FAQs
1. What are the key factors to consider when selecting this potentiometric titrator for laboratory use?
When selecting this potentiometric titrator, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.
2. How often should this potentiometric titrator be calibrated to ensure accurate results?
It is recommended to calibrate this potentiometric titrator at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.
3. What are the common maintenance procedures required for this potentiometric titrator?
Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.
4. Can this potentiometric titrator be used with different types of samples, and are there any compatibility considerations?
Yes, this potentiometric titrator can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.
5. What should be done if the potentiometric titrator malfunctions or produces inconsistent results?
If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.