Introduction
Glassware Washer is an automated cleaning unit offering a capacity of 220L, with an inlet water pressure ranging from 0.3 to 0.8 MPa. Our washer incorporates an air heater and filter for thorough washing and drying ensuring optimized cleaning. Equipped with an efficient pump, for effective circulation of cleaning solutions. It is crafted from stainless steel materials for corrosion resistance making it durable.
This glassware washer is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Glassware Washer is used for washing of various glassware like beakers, pipettes, tubes, plates, dishes etc. in microbiology, biotechnology laboratories, research centres and clinical laboratories.
Specifications
| Capacity | 220 L |
| Washing Temperature | Upto 99℃ |
| Drying Temperature | Upto 120℃ |
| Water consumption/cycle | 20 L |
| Inlet Water Pressure | 0.3 to 0.8 MPa |
| Washing Chamber Size (W × D × H) | 600 × 629 × 690 mm |
| Noise | ≤ 55 dB |
| Overall Power Consumption | 6 kW/ 17 kW |
| Water Washing Power Consumption | 0.75 kW |
| Water Heating Power Consumption | 5/ 15 kW |
| Drying Power Consumption | 3.6 kW |
| Cleaning Racks | 2 pcs |
| Standard Cleaning Racks | 36 nozzles std. 2 racks |
| Power Supply | AC220V, 50Hz; 380V, 50Hz(Standard); 110V,60Hz(Optional) |
| External Size (W×D×H) | 690 × 790 × 1820 mm |
| Package Size (W×D×H) | 790 × 940 × 1990 mm |
| Gross Weight | 300 kg |
Features
touch screen control system
Offers various chamber capacities
Fitted with a glass window
Provided with lockable door for safety
12 preset programs with one customized program
Optimized spray arm and nozzles
FAQs
1. What are the key factors to consider when selecting this glassware washer for laboratory use?
When selecting this glassware washer, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.
2. How often should this glassware washer be calibrated to ensure accurate results?
It is recommended to calibrate this glassware washer at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.
3. What are the common maintenance procedures required for this glassware washer?
Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.
4. Can this glassware washer be used with different types of samples, and are there any compatibility considerations?
Yes, this glassware washer can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.
5. What should be done if the glassware washer malfunctions or produces inconsistent results?
If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.