Introduction

Benchtop Ion meter for I, comes with (I) iodide ion selective electrode for iodide ion concentration measurement. This Ion meter comes with ± 1 % F.S. measurement accuracy. Its direct ion concentration readout helps in elaborate measurement process. The system menu allows setting the 8 parameters like calibration points, stability condition etc. It can measure concentration in ppm, mg / L, mol / L. The mV measurement is used to check the performance of ion selective electrode.

This water testing equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Benchtop Ion meter is used to measure the iodide ion concentration present in potable water, D/W water, waste water and natural water resources using different ion concentration electrodes.

Specifications

Ion measurement range I range: 1×108- 1M, 0.06 -127000 ppm
Ion measurement accuracy ± 1 % F.S.
Resolution 0.001, 0.01, 0.1, 1
Calibration points 2 to 5 points
Calibration solutions 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L
mV range (-1999.9) to 1999.9 mV
mV accuracy ± 0.2 mV
mV resolution 0.1 mV
Temperature measurement range 0 to 105 °C, 32 to 221 °F
Temperature accuracy ± 0.5 °C, ± 0.9 °F
Temperature resolution 0.1°C
Temperature compensation 0 to 100 °C, 32 to 212 °F
Compensation mode Manual or automatic
Data hold function Manual or automatic endpoint detection
Reset function Yes
Stability condition Low or high
Calibration due 0 to 31 days
Power off Manual or automatic (10,20,30 minutes)
Memory Stores up to 500 sets of data
Output communication interface
Connector
Display (130 × 110 mm)
Power DC 5 V, using AC adapter, AC 220 V / 50 Hz
Dimension (L × W × H) 210 × 188 × 60 mm
Weight 1.5 kg

Features

Large display

2 - 5 points calibration from low to high concentration

Direct ion concentration readout for elaborate measurement process

Selectable concentration units from ppm, mg / L, mol / L

mV measurements to check the performance of ion selective electrode

Temperature compensation provides accurate reading over the entire range

Stability indicator to show current measurement status

Calibration due reminder for regular calibration of the meter

Auto hold function to freeze stable reading for better viewing & recording

Automatic electrode diagnosis shows the slope of the sensor

Reset setting function

Expanded memory stores and recalls up to 500 readings

Built –in real time clock stamps

communication interface to transfer stored data to PC

FAQs

1. What types of water samples can It Benchtop Ion meter for I, analyze for iodide ion concentration?

It Benchtop Ion meter for I is designed to accurately measure iodide ion concentrations in potable water, distilled water, wastewater, and natural water sources. It has Iodide Ion Selective Electrode ensuring precise detection even in complex water matrices. This makes it ideal for use in environmental testing, water treatment facilities, and research laboratories. The direct ion concentration readout simplifies and speeds up sample analysis.

2. How does the temperature compensation feature of Benchtop Ion meter for I, improve measurement reliability?

The Benchtop Ion meter for I features both manual and automatic temperature compensation, ensuring that results remain accurate across varying sample temperatures from 0 to 100 °C. This is particularly useful when analyzing samples collected in different environmental conditions. Temperature fluctuations can affect ion activity, so compensation helps maintain consistent readings. This ensures dependable performance in both field and lab settings.

3. Can I track the condition of the ion selective electrode of Benchtop Ion meter for I over time?

Yes, our Benchtop Ion meter for I allows users to monitor electrode performance through its mV measurement mode, which ranges from -1999.9 to 1999.9 mV. This helps detect issues like electrode aging or calibration drift. Additionally, the device features an automatic electrode diagnosis that displays the sensor’s slope, giving a quick insight into electrode health. Regular checks ensure accurate and stable ion measurements.

4. How frequently should the Benchtop Ion meter for I be calibrated and how is the process handled?

The Benchtop Ion meter for I's calibration frequency can be scheduled with reminders set from 0 to 31 days, helping users maintain consistent accuracy. The system supports 2 to 5-point calibration using a wide range of standard solutions. These customizable options ensure accuracy across different concentration levels. The user-friendly menu makes the calibration process straightforward and efficient.

5. Does the Benchtop Ion meter for I support data logging and transfer for record-keeping?

Yes, Benchtop Ion meter for I can store up to 500 sets of readings in its built-in memory, making it easy to manage and review past results. It features a real-time clock for timestamping each data entry, ensuring traceability. A interface allows for quick transfer of stored data to a computer for analysis or archiving. This makes the meter well-suited for regulated lab environments or long-term monitoring projects.

6. What safety and ease-of-use features are included in the Benchtop Ion meter for I?

Benchtop Ion meter for I offers several usability features, including auto-hold to freeze stable readings and manual or automatic endpoint detection. It includes a reset function to restore factory settings and an auto power-off option to prevent energy waste. A stability indicator shows the status of each reading to avoid recording unstable values. These features enhance user confidence and reduce the chance of operator error.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.