Introduction
Benchtop Ion meter for F, comes with (F) fluoride ion selective electrode for fluoride ion concentration measurement. This Ion meter comes with ± 0.5 % F.S. measurement accuracy. The direct ion concentration readout helps in elaborate measurement process. The system menu allows setting the 8 parameters like calibration points, stability condition etc. It can measure concentration in ppm, mg / L, mol / L. The mV measurement is used to check the performance of ion selective electrode.
This water testing equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Benchtop Ion meter is used to measure the fluoride ion concentration present in potable water, D/W water, waste water and natural water resources using different ion concentration electrodes.
Specifications
| Ion measurement range | F range: 1 × 106M – saturation, 0.02 ppm to saturation |
| Ion measurement accuracy | ± 0.5 % F.S. |
| Resolution | 0.001, 0.01, 0.1, 1 |
| Calibration points | 2 to 5 points |
| Calibration solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L |
| mV range | (-1999.9) to 1999.9 mV |
| mV accuracy | ± 0.2 mV |
| mV resolution | 0.1 mV |
| Temperature measurement range | 0 to 105 °C, 32 to 221 °F |
| Temperature accuracy | ± 0.5 °C, ± 0.9 °F |
| Temperature resolution | 0.1°C |
| Temperature compensation | 0 to 100 °C, 32 to 212 °F |
| Compensation mode | Manual or automatic |
| Data hold function | Manual or automatic endpoint detection |
| Reset function | Yes |
| Stability condition | Low or high |
| Calibration due | 0 to 31 days |
| Power off | Manual or automatic (10,20,30 minutes) |
| Memory | Stores up to 500 sets of data |
| Output | communication interface |
| Connector | |
| Display | (130 × 110 mm) |
| Power | DC 5 V, using AC adapter, AC 220 V / 50 Hz |
| Dimension | 210 × 188 × 60 mm |
| Packaging Dimension | 310 × 260 × 200 mm |
| Net Weight | 1.5 kg |
| Gross Weight | 2.5 kg |
Features
Large display
2 - 5 points calibration from low to high concentration
Direct ion concentration readout for elaborate measurement process
Selectable concentration units from ppm, mg / L, mol / L
mV measurements to check the performance of ion selective electrode
Temperature compensation provides accurate reading over the entire range
Stability indicator to show current measurement status
Calibration due reminder for regular calibration of the meter
Auto hold function to freeze stable reading for better viewing & recording
Automatic electrode diagnosis shows the slope of the sensor
Reset setting function
Expanded memory stores and recalls up to 500 readings
Built –in real time clock stamps
communication interface to transfer stored data to PC
FAQs
1. What types of water sources can be tested with It Benchtop Ion meter for F, ?
It Benchtop Ion meter for F is ideal for analyzing fluoride ion concentration in potable water, distilled water, wastewater, and natural water bodies. It has a wide measurement range, from as low as 0.02 ppm up to saturation, makes it suitable for environmental monitoring, municipal water testing, and industrial applications. The fluoride ion selective electrode ensures precise and reliable results across different water types. This versatility makes it a valuable tool for labs and water treatment facilities.
2. How does the Benchtop Ion meter for F help ensure consistent accuracy over time?
The Benchtop Ion meter for F includes a calibration due reminder that alerts users when the meter needs recalibration, with a setting range from 0 to 31 days. Regular calibration is key for ensuring long-term accuracy, especially in high-frequency testing environments. This feature helps maintain optimal electrode performance. It also promotes reliable data for regulatory or quality control requirements.
3. What features of Benchtop Ion meter for F support user-friendly operation during measurements?
Benchtop Ion meter for F has a large display and a direct ion concentration readout, making results easy to view and interpret. Users can select measurement units in ppm, mg/L, or mol/L, depending on their needs. The interface allows customization of key settings like calibration points and stability conditions. These features simplify the testing process and improve workflow efficiency in the lab.
4. Can the Benchtop Ion meter for F be used to check electrode performance?
Yes, Benchtop Ion meter for F includes a mV measurement mode that helps assess the condition and performance of the fluoride ion selective electrode. The automatic electrode diagnostic function also displays the sensor’s slope, offering insight into its effectiveness. This helps users detect when cleaning or replacement is needed. These functions are essential for maintaining measurement reliability.
5. How does the Benchtop Ion meter for F handle changes in sample temperature?
The Benchtop Ion meter for F offers both manual and automatic temperature compensation from 0 to 100°C. This ensures that the fluoride concentration readings remain accurate across different sample temperatures. The included temperature probe monitors real-time values for precise compensation. This is particularly useful when testing environmental samples where temperature variability is common.
6. How does the Benchtop Ion meter for F ensure data is stored and shared efficiently?
Benchtop Ion meter for F has memory capacity to store up to 500 data sets with real-time clock stamps for accurate recordkeeping. The stored data can be transferred easily to a computer via the communication interface. This is useful for compiling reports or maintaining testing logs. It supports traceability and data management in both research and quality assurance contexts.
7. What safety and energy-saving features does the Benchtop Ion meter for F include?
The Benchtop Ion meter for F has manual and automatic power-off options that can be set to 10, 20, or 30 minutes to reduce energy consumption. It operates on a low-voltage 5V DC power adapter, ensuring stable and safe usage. The reset function allows users to restore the device to factory settings. These features help protect the instrument and support user safety during operation.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.