Introduction
Vertical Autoclave has a capacity of 75 litres with a sterilization temperature of 134℃ and sterilization pressure of 0.22 Mpa. Integrated with a digital display and a touch keypad for easy monitoring of the device's working status. Our autoclave consists of a two stainless steel baskets as standard accessory.
It uses high-temperature and high-pressure steam to achieve effective sterilization of laboratory equipment, media, and waste. The advanced control system ensures thorough sterilization while preventing overheating or pressure buildup.Applications
Vertical Autoclaves play a crucial role in pharmaceutical and medical industries by effectively sterilizing glassware, biological materials, and culture media.
Specifications
| Capacity | 75 L |
| Sterilization Temperature | 134℃ |
| Sterilization Pressure | 0.22 Mpa |
| Time Range | 0 to 99 min or 0 to 99 h 59 min |
| Sterilization Temperature Range | 0 to 134℃ |
| Maximum Working Pressure | 0.23 Mpa |
| Heat Average | ≤± 1℃ |
| Power | 4.5 kW |
| Power Supply | AC 220 V, 50 Hz |
| Chamber Volume | 400×600 mm |
| Overall Dimension | 690×470×1140 mm |
| Packing Dimension | 760×550×1290 mm |
| Net Weight | 98 kg |
| Gross Weight | 120 kg |
Features
Incorporate a drying system
Integrated with a self-inflating type seal
Automatic protection over-temperature and over-pressure
Controlled by a microcomputer system
It automatically turns off and sounds a beep alarm
Ensures safe protection in case of water shortage
Features a steam-water inner circulation system
Stainless steel body with a hand wheel-type structure and a safety lock system
FAQs
1. What is the recommended sterilization cycle for different types of laboratory materials?
The recommended cycle depends on the material type: 1) For glassware and heat-resistant materials: 121°C, 15-20 psi, for 15-20 minutes; 2) For liquid media: 121°C, 15-20 psi, for 20-30 minutes (longer for larger volumes); 3) For wrapped instruments: 121°C, 15-20 psi, for 25-30 minutes to ensure steam penetration; 4) For waste materials: 132°C, 30 psi, for 30 minutes for biohazardous waste; 5) For heat-sensitive materials: Use a lower temperature (115°C) for a longer duration (30 minutes) or a specialized cycle if available. Always refer to the material manufacturer's recommendations.
2. How to properly load the autoclave to ensure effective sterilization?
Proper loading is crucial: 1) Place items in a way that allows steam to circulate freely around all surfaces; 2) Avoid overloading the autoclave chamber, leaving at least 2-3 inches of space between items; 3) Stack items with openings facing downward to prevent water accumulation and ensure steam penetration; 4) Use autoclave-compatible containers and avoid sealing them tightly (leave lids loose or use vented caps); 5) Separate different types of materials if possible, especially liquids and solids; 6) Ensure that liquid containers are not filled more than 2/3 full to prevent boiling over.
3. What maintenance procedures are required for the autoclave?
Regular maintenance includes: 1) Draining and cleaning the water reservoir after each use to prevent mineral buildup; 2) Descaling the autoclave monthly (or more frequently in hard water areas) using a recommended descaling agent; 3) Inspecting the door gasket for wear, cracks, or damage and replacing it if necessary; 4) Checking the pressure relief valve and safety interlocks quarterly to ensure proper operation; 5) Cleaning the chamber interior with a mild detergent after each use; 6) Performing annual calibration of temperature and pressure gauges by qualified personnel; 7) Keeping a maintenance log to track all service activities.
4. How to troubleshoot if the autoclave fails to reach the desired temperature or pressure?
If temperature/pressure issues occur: 1) Check if the water level in the reservoir is sufficient; 2) Verify that the door is properly closed and sealed (check gasket for damage); 3) Inspect the heating element for signs of malfunction; 4) Check the pressure relief valve to ensure it is not stuck open; 5) Clean the steam vents and drains to remove any blockages; 6) Ensure the autoclave is properly grounded and the power supply is stable; 7) If the problem persists, do not use the autoclave and contact technical support immediately, as it may pose a safety risk.
5. What safety precautions should be followed when operating the autoclave?
Important safety precautions: 1) Never open the autoclave door while it is pressurized or during the sterilization cycle; 2) Allow the autoclave to cool down and depressurize completely before opening; 3) Wear heat-resistant gloves and eye protection when handling hot items; 4) Stand to the side of the autoclave when opening the door to avoid steam burns; 5) Never autoclave incompatible materials (such as volatile solvents, oils, or explosives); 6) Regularly test the autoclave's performance using biological indicators (spore tests) to ensure effective sterilization; 7) Familiarize yourself with the emergency stop procedures and location of safety devices.