Introduction

Portable Density Meter measures 0 g/cm³ to 3.0 g/cm³ density at a temperature range from 5°C to 55°C suitable for a wide spectrum of liquids in variable temperatures. Our meter offers quick and efficient results with a minimum of 2ml samples. It can change into standard density, concentration, and specific gravity all at once. It has a windproof and dustproof cover that makes it easier to use and lasts longer.

This density meter is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Portable Density Meter is used to measure the density of liquids and is widely utilized in industries such as chemical, pharmaceutical, environmental monitoring, research laboratories, mining, oil, and gas.

Specifications

Density Range 0g/cm³ to 3.0g/cm³
Temperature Range 5℃ to 55℃
Density Accuracy ±0.0005g/cm³
±0.001g/cm³
Temperature Accuracy ± 0.2℃
Repeatability 0.0002g/cm3
Temperature Repeatability 0.1℃
Resolution 0.0001g/cm3
Temperature Resolution 0.01℃
Ambient Temperature -10℃ to 60℃
Sample Size 2ml
Working Time >20 hours
Explosion-Proof Grade Ex ia T4 Ga
Ingress Protection IP67
Storage 5000 sets of data
Interface Bluetooth
Power Rechargeable lithium battery 3.7V
Dimension 245 × 95 × 125 mm
Packaging Dimension 460 × 210 × 400 mm
Net Weight 650 g
Gross Weight 4.08 kg

Features

Lightweight and easy to operate

Supports 5000 sets of data storage

Functions as both a portable and desktop device

Equipped with a U-shaped tube for enhanced measurement accuracy

Extended, reliable, long-lasting battery life

FAQs

1. What are the key factors to consider when selecting this density meter for laboratory use?

When selecting this density meter, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this density meter be calibrated to ensure accurate results?

It is recommended to calibrate this density meter at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this density meter?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this density meter be used with different types of samples, and are there any compatibility considerations?

Yes, this density meter can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the density meter malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.