Introduction

High Speed Centrifuge features a maximum speed of 16000 rpm with a maximum of 27170 × g. It can effortlessly switch between low-speed and high-speed spinning modes, accommodating both swing-out and angle rotors. The centrifuge features a digital display that shows the parameters like rpm, and time for real-time monitoring. Its body is made of high-quality steel ensuring durability and a safe and reliable operation. Our centrifuge is designed for efficient separation of components within biological samples.

It utilizes high-speed rotation to separate components of different densities, widely used in biological, medical, and chemical laboratories. The unit is equipped with safety protection systems to ensure operator safety during high-speed operation.

Applications

Our High Speed Centrifuge finds extensive application in animal and plant molecular biology for the isolation of cellular components. It is ideal for purifying microorganisms, viruses, bacteria, proteins, nucleic acids, and subcellular organelles with high precision and efficiency.

Specifications

Max. Speed 16000 rpm
Max. 27170 × g
Max. Capacity 4 × 600 mL
Time Range 0 to 99min
/ Convert Yes
Noise Up to 65 dB
Temperature Normal
Acc/Dec 10 rates
Speed Accuracy ± 20r/min
Power Supply AC220V/110V 50HZ/60HZ
Dimension (L × W × H) 700 × 500 × 400 mm
Net Weight 67 Kg
Gross Weight 85 Kg

Features

Maintenance-free brushless motor

Automatic electric lid lock

Over-speed and imbalance protection function

Flexibility to adjust settings during operation

Table-top design

FAQs

1. What is the maximum sample volume that can be processed in the centrifuge?

The maximum sample volume depends on the type of rotor used with the centrifuge. Typical rotors can accommodate sample volumes ranging from 0.2 mL (microcentrifuge tubes) to 50 mL (conical tubes) or larger for specialized rotors. It is important to check the centrifuge's specifications and rotor compatibility to ensure that the sample volume does not exceed the recommended limits, which could affect centrifugation efficiency and safety.

2. How to balance the centrifuge before operation?

Proper balancing is critical for safe and effective centrifuge operation: 1) Ensure that all sample tubes have the same volume and weight; 2) Place the tubes symmetrically in the rotor, opposite each other; 3) For odd numbers of samples, use a balance tube filled with the same volume of appropriate solution; 4) Check that the rotor is properly seated and secured in the centrifuge; 5) Avoid overloading the rotor beyond its maximum capacity.

3. What is the difference between relative centrifugal force (RCF) and revolutions per minute (RPM)?

RCF is a measure of the centrifugal force applied to the sample, expressed in multiples of gravity (x g), and depends on both the RPM and the radius of the rotor. RPM is a measure of the rotor's rotation speed in revolutions per minute. The relationship between RCF and RPM is given by the formula: RCF = 1.118 × 10^-5 × r × RPM² (where r is the rotor radius in centimeters). For most applications, RCF is the preferred parameter as it directly relates to the separation efficiency, regardless of rotor size.

4. How to maintain the centrifuge to ensure long service life?

Regular maintenance includes: 1) Cleaning the rotor and chamber after each use to remove sample spills and debris; 2) Inspecting the rotor for cracks, corrosion, or wear before each use; 3) Lubricating moving parts according to the manufacturer's recommendations; 4) Calibrating the speed and temperature controls annually or after major service; 5) Ensuring proper ventilation around the centrifuge to prevent overheating; 6) Storing the centrifuge in a clean, dry environment when not in use.

5. What safety precautions should be taken when using the centrifuge?

Important safety precautions include: 1) Always balance the sample tubes properly before operation; 2) Ensure the rotor is correctly installed and secured; 3) Do not open the centrifuge lid while the rotor is still spinning; 4) Use appropriate personal protective equipment (gloves, goggles) when handling samples and cleaning the equipment; 5) Avoid overloading the centrifuge beyond its maximum capacity; 6) Regularly inspect the centrifuge for any signs of damage or malfunction and discontinue use if any issues are found.