Introduction

Temperature and Humidity Test Chamber is a touchscreen controller with programming, has a capacity of 1500 liters. A conductive coating is applied to the interior of tempered glass windows in a dynamic design to prevent frosting. The interior is comprised of 304 stainless steels, which resists moisture corrosion and rusting. Designed to provide excellent insulation performance, resistance to degradation, and noise reduction.

This test equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Temperature and Humidity Test Chamber is extensively utilized for performing tests under controlled conditions across pharmaceutical, chemical, food, and beverage sectors as well as fundamental and advanced research.

Specifications

Capacity 1500 L
Temperature range (-60) ℃ to +150 ℃
Environmental conditions 5℃ to +35 ℃ ≤ 85% RH
Loading weight ≥ 150 Kg
Temperature cooling rate 3 ℃ / min
Temperature heating rate 3 ℃ / min
Temperature deviation ± 1.0 ℃
Heating element Nichrome heater
Humidity range 10% to 98% RH
Humidity deviation ± 2.5 % RH
Maximum noise 65 dBA
Safety features Humidifier dry-combustion protection, over-temperature protection, over-current protection, Refrigerant high-pressure protection, Water shortage protection, Earth leakage protection
Controller Programmable color touch screen controller
Communication Ethernet connection, port
Internal dimension (D × W × H) 1000 × 1500 × 1000 mm
Overall dimension (D × W × H) 1300 × 2340 × 2200 mm

Features

304 Stainless steel design provides corrosion resistance

Rugged and durable construction ensures longevity of machine

Test hole with a stainless-steel flange prevents moisture from entering the insulation layer

Tempered glass window with a conductive film on the interior glass to prevent frosting

Built-in lighting for observing samples

programmable color touch screen controller for ease of operation

Ethernet interface and port for connectivity

Ability to preset testing programs based on user requirements

Controller features buttons for , Ethernet, Lighting, Emergency, and Power

Electronic humidification system for user convenience

Designed for high humidity tests in a walk-in chamber

Quick and high-performance humidification

Offers excellent insulation performance, resistance to degradation, and noise reduction

Electrostatic treatment for added protection

Resistant to high and low-temperature corrosion

High hardness and anti-impact properties

Enhanced safety factor

FAQs

1. What are the key factors to consider when selecting this test equipment for laboratory use?

When selecting this test equipment, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this test equipment be calibrated to ensure accurate results?

It is recommended to calibrate this test equipment at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this test equipment?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this test equipment be used with different types of samples, and are there any compatibility considerations?

Yes, this test equipment can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the test equipment malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.