Introduction

Orbital Shaker is designed for shaking, mixing and aeration applications. It is compact with micro-computer control technology. It features adjustable speed control that provides gentle to vigorous agitation. The low noise and stable operation makes it suitable for use in different laboratories like molecular biology, microbiology, immunology, chemistry, etc. This laboratory shakers is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

This product is suitable for cell culturing, staining/de-staining and general mixing inmicrobiology, chemistry, immunology, biochemistry, molecular biology, biopharmaceutical and biomedical laboratories.

Specifications

Shaking Speed Range 20 - 300 rpm
Platform Dimension 350 x 260 mm
Shaking Orbit 20 mm
Shaking Motion Orbital
Display Analog
Timer Range 1-9999 min
Temperature Range None
Operation Continuous/Timed
Power 110 W
Power Supply 220 V , 60 Hz

Features

Easy to clean anti-eroding stainless steel or alnico plate Microprocessor based controller with timing function Brushless DC motor ensures maintenance-free, reliable and quiet operation Audio alarm signals program completion Smooth start and stop system prevents liquid spillage Programmable controller with screen Heating plate function Over-temperature alarm

FAQs

1. What are the key factors to consider when selecting this laboratory shakers for laboratory use?

When selecting this laboratory shakers, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this laboratory shakers be calibrated to ensure accurate results?

It is recommended to calibrate this laboratory shakers at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this laboratory shakers?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this laboratory shakers be used with different types of samples, and are there any compatibility considerations?

Yes, this laboratory shakers can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the laboratory shakers malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.