Introduction
Low speed Centrifuge is a compact and tabletop unit, offers maximum speed of 6000 rpm and 4730×g of maximum with 4×800 ml of capacity. Features microprocessor control and 10 kinds of acceleration/deceleration speed with 0 to 99 min of time range. Designed with high quality steel housing with automatic electric lid lock, has specialized taper sleeve to connect spindle and rotor. Equipped with brushless DC motor and digital display for simple operation, supports / conversion and provides protection against over-temperature and imbalance.
It utilizes high-speed rotation to separate components of different densities, widely used in biological, medical, and chemical laboratories. The unit is equipped with safety protection systems to ensure operator safety during high-speed operation.Applications
Low Speed Centrifuge is used for the routine separation of samples across biochemical products, scientific and technological research, food safety, medical and health, blood stations, hospital, medical science, technology, education, production sector, molecular, biochemical, sanitation etc.
Specifications
| Maximum Speed | 6000 rpm |
| Maximum | 4730×g |
| Maximum Capacity | 4×800 ml |
| Time Range | 0 to 99 min |
| Speed Accuracy | ± 20 rpm |
| Temperature | Normal |
| Display | Digital |
| Motor | Brushless Motor |
| Acceleration/Deceleration | 10 kinds |
| / Convert | Yes |
| Protection | Over-temperature and Imbalance |
| Noise | ≤ 58 dB |
| Power Supply | AC 220/110 V, 50/60 Hz |
| Dimension (W×D×H) | 685×500×385 mm |
| Net Weight | 67 kg |
Features
A compact and tabletop unit with 4×800 ml of capacity
Maximum speed of 6000 rpm and 4730×g of maximum
Microprocessor control, stable and reliable operation
10 kinds of acceleration/deceleration speed, smooth operation
High quality steel housing with automatic electric lid lock
Specialized taper sleeve to connect spindle and rotor
Brushless DC motor, long lifespan and quiet operation
Digital display, convenient setting and monitoring of parameters
Protection against over-temperature and imbalance
/ conversion, easy and reliable results
High-efficient, reliable and stable unit
FAQs
1. What is the maximum sample volume that can be processed in the centrifuge?
The maximum sample volume depends on the type of rotor used with the centrifuge. Typical rotors can accommodate sample volumes ranging from 0.2 mL (microcentrifuge tubes) to 50 mL (conical tubes) or larger for specialized rotors. It is important to check the centrifuge's specifications and rotor compatibility to ensure that the sample volume does not exceed the recommended limits, which could affect centrifugation efficiency and safety.
2. How to balance the centrifuge before operation?
Proper balancing is critical for safe and effective centrifuge operation: 1) Ensure that all sample tubes have the same volume and weight; 2) Place the tubes symmetrically in the rotor, opposite each other; 3) For odd numbers of samples, use a balance tube filled with the same volume of appropriate solution; 4) Check that the rotor is properly seated and secured in the centrifuge; 5) Avoid overloading the rotor beyond its maximum capacity.
3. What is the difference between relative centrifugal force (RCF) and revolutions per minute (RPM)?
RCF is a measure of the centrifugal force applied to the sample, expressed in multiples of gravity (x g), and depends on both the RPM and the radius of the rotor. RPM is a measure of the rotor's rotation speed in revolutions per minute. The relationship between RCF and RPM is given by the formula: RCF = 1.118 × 10^-5 × r × RPM² (where r is the rotor radius in centimeters). For most applications, RCF is the preferred parameter as it directly relates to the separation efficiency, regardless of rotor size.
4. How to maintain the centrifuge to ensure long service life?
Regular maintenance includes: 1) Cleaning the rotor and chamber after each use to remove sample spills and debris; 2) Inspecting the rotor for cracks, corrosion, or wear before each use; 3) Lubricating moving parts according to the manufacturer's recommendations; 4) Calibrating the speed and temperature controls annually or after major service; 5) Ensuring proper ventilation around the centrifuge to prevent overheating; 6) Storing the centrifuge in a clean, dry environment when not in use.
5. What safety precautions should be taken when using the centrifuge?
Important safety precautions include: 1) Always balance the sample tubes properly before operation; 2) Ensure the rotor is correctly installed and secured; 3) Do not open the centrifuge lid while the rotor is still spinning; 4) Use appropriate personal protective equipment (gloves, goggles) when handling samples and cleaning the equipment; 5) Avoid overloading the centrifuge beyond its maximum capacity; 6) Regularly inspect the centrifuge for any signs of damage or malfunction and discontinue use if any issues are found.