Introduction

Low Speed Centrifuge is a microcomputer-controlled unit with 8×20 ml of capacity, features 4000 rpm speed range with1880×g of at normal temperature. Compact design with digital display, brushless motor and electric cover lock, offers protection against super speed and imbalance. Equipped with 10 kinds of acceleration/deceleration and / conversion, provides smooth operation with low noise and small vibration.

It utilizes high-speed rotation to separate components of different densities, widely used in biological, medical, and chemical laboratories. The unit is equipped with safety protection systems to ensure operator safety during high-speed operation.

Applications

Low Speed Centrifuge is used for the routine separation of samples across biochemical products, scientific and technological research, food safety, medical and health, blood stations, hospital medical science and technology education and production sector molecular biochemical, sanitation etc.

Specifications

Maximum Speed 4000 rpm
Maximum 1880×g
Maximum Capacity 8×20 ml
Time Range 0 to 99 min
Speed Accuracy ± 20 rpm
Temperature Normal
Display Digital
Motor Brushless Motor
Acceleration/Deceleration 10 kinds
/ Convert Yes
Protection Super speed and Imbalance
Noise ≤ 55 dB
Power Supply AC 220/110 V, 50/60 Hz
Dimension (W×D×H) 310×270×220 mm
Net Weight 6.5 kg

Features

A microcomputer-controlled unit with 8×20 ml of capacity

4000 rpm speed range with1880×g of at normal temperature

Digital display, for convenient monitoring and setting of different parameters

Brushless motor, quick acceleration and deceleration

Electric cover lock, safe and secure operation

Protection against super speed and imbalance, reliable operation

10 kinds of acceleration/deceleration and / conversion

Compact design, ideal for laboratories and hospital

Smooth operation with low noise and small vibration

High-efficient, stable and reliable unit

FAQs

1. What is the maximum sample volume that can be processed in the centrifuge?

The maximum sample volume depends on the type of rotor used with the centrifuge. Typical rotors can accommodate sample volumes ranging from 0.2 mL (microcentrifuge tubes) to 50 mL (conical tubes) or larger for specialized rotors. It is important to check the centrifuge's specifications and rotor compatibility to ensure that the sample volume does not exceed the recommended limits, which could affect centrifugation efficiency and safety.

2. How to balance the centrifuge before operation?

Proper balancing is critical for safe and effective centrifuge operation: 1) Ensure that all sample tubes have the same volume and weight; 2) Place the tubes symmetrically in the rotor, opposite each other; 3) For odd numbers of samples, use a balance tube filled with the same volume of appropriate solution; 4) Check that the rotor is properly seated and secured in the centrifuge; 5) Avoid overloading the rotor beyond its maximum capacity.

3. What is the difference between relative centrifugal force (RCF) and revolutions per minute (RPM)?

RCF is a measure of the centrifugal force applied to the sample, expressed in multiples of gravity (x g), and depends on both the RPM and the radius of the rotor. RPM is a measure of the rotor's rotation speed in revolutions per minute. The relationship between RCF and RPM is given by the formula: RCF = 1.118 × 10^-5 × r × RPM² (where r is the rotor radius in centimeters). For most applications, RCF is the preferred parameter as it directly relates to the separation efficiency, regardless of rotor size.

4. How to maintain the centrifuge to ensure long service life?

Regular maintenance includes: 1) Cleaning the rotor and chamber after each use to remove sample spills and debris; 2) Inspecting the rotor for cracks, corrosion, or wear before each use; 3) Lubricating moving parts according to the manufacturer's recommendations; 4) Calibrating the speed and temperature controls annually or after major service; 5) Ensuring proper ventilation around the centrifuge to prevent overheating; 6) Storing the centrifuge in a clean, dry environment when not in use.

5. What safety precautions should be taken when using the centrifuge?

Important safety precautions include: 1) Always balance the sample tubes properly before operation; 2) Ensure the rotor is correctly installed and secured; 3) Do not open the centrifuge lid while the rotor is still spinning; 4) Use appropriate personal protective equipment (gloves, goggles) when handling samples and cleaning the equipment; 5) Avoid overloading the centrifuge beyond its maximum capacity; 6) Regularly inspect the centrifuge for any signs of damage or malfunction and discontinue use if any issues are found.