Introduction

is a high speed refrigerated centrifuge having 21000 rpm speed. It is safe, reliable and user friendly instrument equipped with brushless frequency motor, display, flexible axle driven rotor system, automatic electric lid lock system etc. and delivers highly precise results.

It utilizes high-speed rotation to separate components of different densities, widely used in biological, medical, and chemical laboratories. The unit is equipped with safety protection systems to ensure operator safety during high-speed operation.

Applications

It is widely used in life sciences, healthcare and pharmaceutical industries for extraction, protein precipitation and sample processing.

Specifications

Max. Speed 21000 rpm
Max. 29670 x g
Max. Capacity 4 x 500 ml
Temp. Range -20°C to 40°C
Temp. Accuracy ± 1 ℃
Speed Accuracy ± 50 rpm
Timer Range 1 - 99 hr. 59 min
Noise ≤ 58 dB
Power Supply AC 110 -220 V / 50 - 60 Hz / 15A
Dimension (H x W x D) 690 × 715 × 430 mm
Packaged Dimension (H x W x D) 875 x 785 x 560 mm
Net Weight 125 kg
Gross Weight 150 kg

Features

Dual core processor making it high/low speed and large/small capacity compatible

Flexible axle driven rotor system that ensures smooth functioning

3 tier protection steel covering to ensure safety

10 inches display that indicates all running parameters

Automatic electric locking system that ensures protection against over speed, over temperature and imbalance

Enables easy and quick loading of samples

Provision to change running parameters

100 different programs can be stored in the memory

10 different acceleration and deceleration speed available

Rotor is connected to spindle by specialized taper sleeve

Wide range of rotors that are compatible with the instrument are available

Adapters can be designed as per the experimental requirement

Safe, reliable and efficient

Pollution free

FAQs

1. What is the maximum sample volume that can be processed in the centrifuge?

The maximum sample volume depends on the type of rotor used with the centrifuge. Typical rotors can accommodate sample volumes ranging from 0.2 mL (microcentrifuge tubes) to 50 mL (conical tubes) or larger for specialized rotors. It is important to check the centrifuge's specifications and rotor compatibility to ensure that the sample volume does not exceed the recommended limits, which could affect centrifugation efficiency and safety.

2. How to balance the centrifuge before operation?

Proper balancing is critical for safe and effective centrifuge operation: 1) Ensure that all sample tubes have the same volume and weight; 2) Place the tubes symmetrically in the rotor, opposite each other; 3) For odd numbers of samples, use a balance tube filled with the same volume of appropriate solution; 4) Check that the rotor is properly seated and secured in the centrifuge; 5) Avoid overloading the rotor beyond its maximum capacity.

3. What is the difference between relative centrifugal force (RCF) and revolutions per minute (RPM)?

RCF is a measure of the centrifugal force applied to the sample, expressed in multiples of gravity (x g), and depends on both the RPM and the radius of the rotor. RPM is a measure of the rotor's rotation speed in revolutions per minute. The relationship between RCF and RPM is given by the formula: RCF = 1.118 × 10^-5 × r × RPM² (where r is the rotor radius in centimeters). For most applications, RCF is the preferred parameter as it directly relates to the separation efficiency, regardless of rotor size.

4. How to maintain the centrifuge to ensure long service life?

Regular maintenance includes: 1) Cleaning the rotor and chamber after each use to remove sample spills and debris; 2) Inspecting the rotor for cracks, corrosion, or wear before each use; 3) Lubricating moving parts according to the manufacturer's recommendations; 4) Calibrating the speed and temperature controls annually or after major service; 5) Ensuring proper ventilation around the centrifuge to prevent overheating; 6) Storing the centrifuge in a clean, dry environment when not in use.

5. What safety precautions should be taken when using the centrifuge?

Important safety precautions include: 1) Always balance the sample tubes properly before operation; 2) Ensure the rotor is correctly installed and secured; 3) Do not open the centrifuge lid while the rotor is still spinning; 4) Use appropriate personal protective equipment (gloves, goggles) when handling samples and cleaning the equipment; 5) Avoid overloading the centrifuge beyond its maximum capacity; 6) Regularly inspect the centrifuge for any signs of damage or malfunction and discontinue use if any issues are found.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.