Introduction
Refrigerated Centrifuge is a microprocessor controlled floor standing refrigerated centrifuge having 5000 rpm speed. It is safe, reliable, low maintenance and easy-to-use instrument equipped with display and low noise flexible axle driven rotor system. With auto electric locking system fluorine free compressors and 3 tier protective steel covering, it is ideal for blood separation, protein precipitation etc. and can be used at blood station and pharmaceutical industry for variety of applications.
It utilizes high-speed rotation to separate components of different densities, widely used in biological, medical, and chemical laboratories. The unit is equipped with safety protection systems to ensure operator safety during high-speed operation.Applications
It is widely used in biochemical and clinical labs for precipitate separation and serum analysis, in pharmaceutical industry etc. and is perfect for , , or antibody analysis.
Specifications
| Max. Speed | 5000 rpm |
| Max. | 4730 x g |
| Max. Capacity | 4 x 500 ml |
| Temp. Range | -20°C to 40°C |
| Temp. Accuracy | ± 1 ℃ |
| Speed Accuracy | ± 50 rpm |
| Timer Range | 0 - 99 hr. 59 min |
| Noise | ≤ 58 dB |
| Rotor Identification | Automatic |
| Power Supply | AC 110 - 220 V/ 50 - 60 Hz / 15 A |
| Dimension (H x W x D) | 685 x 540 x 820 mm |
| Packaged Dimension (H x W x D) | 845 x 585 x 515 mm |
| Net Weight | 170 kg |
| Gross Weight | 190 kg |
Features
Microprocessor controlled system
display that indicates speed, time and in operation
3 tiers protective steel covering
Low noise flexible axle driven rotor system which ensures smooth functioning
Brushless frequency conversion motor
Fluorine free compressors with double cycle cooling and heating system
Automatic electric lid lock that provides protection against over speed and temperature and imbalance
Rotor is connected to spindle by specialized taper sleeve
Enables easy and quick loading of samples
Optional rotors available
Safe, reliable and easy-to-use
Low maintenance
Environment friendly
FAQs
1. What is the maximum sample volume that can be processed in the centrifuge?
The maximum sample volume depends on the type of rotor used with the centrifuge. Typical rotors can accommodate sample volumes ranging from 0.2 mL (microcentrifuge tubes) to 50 mL (conical tubes) or larger for specialized rotors. It is important to check the centrifuge's specifications and rotor compatibility to ensure that the sample volume does not exceed the recommended limits, which could affect centrifugation efficiency and safety.
2. How to balance the centrifuge before operation?
Proper balancing is critical for safe and effective centrifuge operation: 1) Ensure that all sample tubes have the same volume and weight; 2) Place the tubes symmetrically in the rotor, opposite each other; 3) For odd numbers of samples, use a balance tube filled with the same volume of appropriate solution; 4) Check that the rotor is properly seated and secured in the centrifuge; 5) Avoid overloading the rotor beyond its maximum capacity.
3. What is the difference between relative centrifugal force (RCF) and revolutions per minute (RPM)?
RCF is a measure of the centrifugal force applied to the sample, expressed in multiples of gravity (x g), and depends on both the RPM and the radius of the rotor. RPM is a measure of the rotor's rotation speed in revolutions per minute. The relationship between RCF and RPM is given by the formula: RCF = 1.118 × 10^-5 × r × RPM² (where r is the rotor radius in centimeters). For most applications, RCF is the preferred parameter as it directly relates to the separation efficiency, regardless of rotor size.
4. How to maintain the centrifuge to ensure long service life?
Regular maintenance includes: 1) Cleaning the rotor and chamber after each use to remove sample spills and debris; 2) Inspecting the rotor for cracks, corrosion, or wear before each use; 3) Lubricating moving parts according to the manufacturer's recommendations; 4) Calibrating the speed and temperature controls annually or after major service; 5) Ensuring proper ventilation around the centrifuge to prevent overheating; 6) Storing the centrifuge in a clean, dry environment when not in use.
5. What safety precautions should be taken when using the centrifuge?
Important safety precautions include: 1) Always balance the sample tubes properly before operation; 2) Ensure the rotor is correctly installed and secured; 3) Do not open the centrifuge lid while the rotor is still spinning; 4) Use appropriate personal protective equipment (gloves, goggles) when handling samples and cleaning the equipment; 5) Avoid overloading the centrifuge beyond its maximum capacity; 6) Regularly inspect the centrifuge for any signs of damage or malfunction and discontinue use if any issues are found.