Introduction

Nucleic Acid Extraction system is fully automated compact system designed to efficiently isolate and from multiple sample types, including whole blood, tissue, cells, plants and viruses. This compact unit can process 8 samples up to 500 µL in a single run making efficient use of laboratory bench space. The most significant advantage is the reliability of the isolated nucleic acid and the technology utilizes an ultra-thin polymer membrane for efficient capture of nucleic acids, allowing for isolation of high quality, high yield or . This nucleic acid extraction system is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

This device is compatible with diagnostics kits and also has requirement in several fields such as Forensic Samples, Sequencing, Cloning, Routine sample preparation, Genetic screening, Microbiology testing and Plant molecular biology research.

Specifications

Sample Capacity 1 to 8 samples
Sample Volume 20 to 500 µl
Working Volume 200 to 1000 µl
Extraction Time 15 to 40 minutes
Extraction Method Magnetic beads
Magnetic Bead Recovery ≥ 98%
Open System Apply to different magnetic beads reagents
Sample Lysis Controlled temperature function
Product Purity A260/A280 ≥ 1.7–2.0; ≥ 1.8–2.1
Power Supply AC 100V–240V, 50-60Hz
External Size (W×D×H) 285×280×295 mm
Package Size (W×D×H) 385×370×395 mm
Net Weight 7.5 kg
Gross Weight 14.5 kg

Features

Automated / extraction

System uses pre-filled cartridges that can run independently

High purity of product

Fully automated and easy to operate

High throughput, can process 1-96 samples at a single stretch

Optimization of extraction process with professional extraction kit

Large capacity program

Constant temperature function to ensure best reaction speed during the purification process

Friendly operation interface

Portable, light-weight and durable

Versatile liquid handling options

Built-in touch screen

FAQs

1. What are the key factors to consider when selecting this nucleic acid extraction system for laboratory use?

When selecting this nucleic acid extraction system, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this nucleic acid extraction system be calibrated to ensure accurate results?

It is recommended to calibrate this nucleic acid extraction system at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this nucleic acid extraction system?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this nucleic acid extraction system be used with different types of samples, and are there any compatibility considerations?

Yes, this nucleic acid extraction system can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the nucleic acid extraction system malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.