Introduction
Double Beam UV-Vis Spectrophotometer is a compact, tabletop, wide screen double beam spectrophotometer comprising double beam long light path design, offers 190 to 1100 nm of wavelength range with 1200 L/mm grating. Features automatic calibration of all baseline, wavelength, and dark current, it has rigid 16 mm dicast aluminium base as optical mount. Equipped with 6 inches display, standard software and interface, this spectrometer provides direct operation to multi functions and display the test results curve and data. With unique 520 mm long light path, it ensures great resolution with stability and reliability.
This analytical equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Double Beam UV-Visible Spectrophotometer are used for analysis of band gap, optical coatings and thin films, quantitative analyses, kinetics, wavelength scanning, and and Protein analysis across clinical and research laboratories.
Specifications
| Wavelength range | 190 to 1100 nm |
| Spectral bandwidth | 1.8 nm |
| Optical system | Double beam; 1200 lines/mm grating |
| Wavelength accuracy | ±0.1nm (D2 656.1nm), ±0.3nm @ all |
| Wavelength repeatability | 0.2 nm |
| Photometric range | -0.3 to 3 A; 0 to 200% T; 0 to 9999 C |
| Photometric accuracy | ±0.2% T (0 to 100% T) |
| Photometric repeatability | ≤0.1% T (0 to 100% T) |
| Noise | ± 0.0005 A/h |
| Light source | Tungsten lamp, Deuterium lamp |
| Stray light | ≤0.03% T @ 220 nm,360 nm |
| Stability | ± 0.001 A/h @ 500nm |
| Display | 320×240 Dots (6 inches) display |
| Baseline Flatness | ±0.001A/h |
| Detector | Silicon photodiode |
| Function | Spectrum scanning, Standard curve, Kinetics, Multi wavelength scanning, /Protein testing |
| Interface | |
| Printer | Parallel port |
| PC software | Yes |
| Power supply | AC 220 V/110 V,50/60 Hz |
| Dimensions (W×D×H) | 625×430×206 mm |
| Weight | 30 kg |
Features
Wide screen double beam spectrophotometer
Unique double beam 520 mm long light path design
190 to 1100 nm of wavelength range with 1200 L/mm grating
Automatic calibration of all baseline, wavelength, and dark current
Rigid 16 mm dicast aluminium base as optical mount
6 inches display, standard software and interface
Direct operation to multi functions: spectrum scanning, standard curve, kinetics, multi wavelength scanning, /Protein testing
Tungsten and deuterium lamp as light source
Great resolution with stability and reliability
FAQs
1. What are the key factors to consider when selecting this analytical equipment for laboratory use?
When selecting this analytical equipment, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.
2. How often should this analytical equipment be calibrated to ensure accurate results?
It is recommended to calibrate this analytical equipment at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.
3. What are the common maintenance procedures required for this analytical equipment?
Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.
4. Can this analytical equipment be used with different types of samples, and are there any compatibility considerations?
Yes, this analytical equipment can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.
5. What should be done if the analytical equipment malfunctions or produces inconsistent results?
If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.