Introduction
Biological Microscope has design of Siedentopf type trinocular viewing head, inclined at 30°, 360° rotation, and interpupillary distance of 48 to76 mm. This Microscope has attachment of Epi-fluorescence Koehler illuminator system, field diaphragm with center adjustable. Coaxial coarse and fine focusing adjustment with rack and pinion mechanism fine focusing interval 0.002 mm.
This microscope is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Biological-Microscope is used in microbiology, cytobiology, cell and tissue culture, cell engineering and hybridoma technique and other modern biological research also used for dynamic observation of the crystal surface growth and micro topography.
Specifications
| Viewing head | Siedentopf type trinocular head (dual light transform) inclined at 30°, 360° rotation, interpupillary adjustable distance 48 to 76 mm |
| Optical System | Infinite Optical System |
| Light distribution | 100: 0 (100% for eyepiece) 80: 20 (80% for trinocular head and 20% for eyepiece) |
| Eyepiece | WF 10X / 23 mm (adjustable) |
| Objective | Infinite plan objective 4X, 10X, 20X, 40X (s), 100X(s, oil) |
| Stage | Integrated stage, stage size: 182×140 mm and Travel range: 77×52 mm, Two slide holder |
| Epi-fluorescence FLED2 system | 5W- Epi fluorescence unit, B and G Excitation Filters, Power Source, 5W Lamp House, Centering Objective, Digital Camera 5.0 MP |
| Condenser | N.A. 0.9/0.13, swing out with iris diaphragm |
| Focusing | Coaxial coarse and fine focusing adjustment with rack and pinion mechanism fine focusing interval 0.002 mm |
| Nosepiece | Quintuple |
| Illumination | Built in Koehler illuminator system 6V/30 W Halogen lamp, field diaphragm, centre adjustable |
| Filter | Blue |
| C- mount | 0.57 × C-mount (focus adjustment) |
| Packing dimension | 525 × 470 × 490 mm |
| Weight | 20 kg |
Features
Siedentopf trinocular head, Inclined 30° and rotatable 360°
Epi-fluorescence system to make for fluorescence purpose
Designed with infinite plan objective 4X, 10X, 20X, 40X (s), 100X(s, oil)
Built in Koehler illuminator system 6V/30 W Halogen lamp, field diaphragm, centre adjustable
Designed with quintuple nosepiece
WF 10X / 23 mm (adjustable) eyepiece
N.A. 0.9/0.13, swing out with iris diaphragm Condenser
FAQs
1. What are the key factors to consider when selecting this microscope for laboratory use?
When selecting this microscope, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.
2. How often should this microscope be calibrated to ensure accurate results?
It is recommended to calibrate this microscope at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.
3. What are the common maintenance procedures required for this microscope?
Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.
4. Can this microscope be used with different types of samples, and are there any compatibility considerations?
Yes, this microscope can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.
5. What should be done if the microscope malfunctions or produces inconsistent results?
If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.