Introduction

Microwave Digestion System features a 50 ml capacity with precise temperature control ranging from 50 to 400 °C. Its aluminium body and -controlled temperature system ensure automatic temperature adjustment for enhanced accuracy. Featured with inner vessel and glass outer vessel offer excellent corrosion resistance. Our Microwave Digestion System is perfect for industries like food, textiles, metallurgy, bio-pharma, petrochemicals, wastewater treatment, and cosmetics.

This microwave digestion system is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Our Microwave Digestion System is widely used to dissolve compounds like heavy metals, inorganic substances, filters, and sediments in industries such as food, textiles, plastics, geology, metallurgy, coal, bio-pharma, petrochemicals, environmental monitoring, wastewater treatment, battery manufacturing, cosmetics, and more.

Specifications

Sample quantity 40 per batch
Chamber volume 50 ml
Rotation mode 360° continuous rotation
Microwave power 0 to 3000 W adjustable
Microwave frequency 2450 MHz
Pressure control range 0 to 10 MPa
Maximum working pressure 6 MPa
Pressure control accuracy 0.01 MPa
Outer vessel pressure limit 20 MPa
Temperature control range 50 to 400 °C
Maximum working temperature 250 °C
Temperature control accuracy ± 0.3 °C
Inner vessel temperature limit 300 °C
Microwave leak < 5 mW / cm6
Inner vessel material
Outer vessel material + glass fiber
Explosion proof frame Polypropylene Glass Fiber
Temperature testing Contactless
Pressure testing Contactless
Display 8 inch touch screen
Power AC 220 V 16A , 50 Hz / 60 Hz
Dimension 640 x 630 x 590 mm
Packaging Dimension Wooden Case 800 × 800 × 810 mm
Carton 570 × 570 × 660 mm
Net weight 78 kgs
Gross Weight Wooden Case 110 kg
Carton 45 kg

Features

Alarm sensor

Multi-fibre pressure monitoring

255 program storage

Automatic calibration & troubleshooting

High-strength double security door

Instrument fault monitoring alert

Multiple safety protections

Explosion-proof security doors

Lid-locking system

coating

Heating block

Acid removal

Instants reseal

Organic sample analysis

FAQs

1. What are the key factors to consider when selecting this microwave digestion system for laboratory use?

When selecting this microwave digestion system, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this microwave digestion system be calibrated to ensure accurate results?

It is recommended to calibrate this microwave digestion system at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this microwave digestion system?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this microwave digestion system be used with different types of samples, and are there any compatibility considerations?

Yes, this microwave digestion system can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the microwave digestion system malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.