Melting Point Apparatus offers desktop design, Semi- automatic detection method, with cooling function. Equipped with Peltier precise temperature function, In line with international standards such as CE & for determination of the melting point of oils and fats. With addition of either high-definition camera or high definition video and camera technology, to delivers accurate, stable results, and user can clearly see the whole process of sample melting, automatic detection to eliminate the subjective error to determine the melting point.
This melting point apparatus is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
It finds application across finding meting point of oil and fat in food and drug industry, biochemistry, medicines, mining, water management industry.
Specifications
| Temperature control range | 6 to 100℃ |
| Detection method | Semi-automatic |
| Capacity per batch | 2 pcs/batch |
| Temperature resolution | 0.1℃ |
| Temperature gradients | (0.1 to 10.0)℃/Min |
| Temperature accuracy | ±0.3℃ |
| Repeatability | 0.1℃/Min , ±0.1℃ |
| Camera & Video | Camera & Video |
| Video playback | Yes |
| Operator account | 8 |
| Result storage | 400 |
| SD card capacity | 8G |
| Display | Touch screen |
| Interface | RS232 SD card Enternet |
| Opening capillary size | I.D>1.0 mm, O.D.1.4 mm Double opening |
| Power | 110 to 220V 50, 60HZ 120W |
| Dimension | 400 × 280× 330 mm |
| Weight | 5 kg |
Features
touch screen display
Semi- automatic detection method, with cooling function
Capacity per batch is 2 pcs
Designed with a key automatic detection function
Use of double opening capillary size I.D>1.0 mm,O.D.1.4 mm
In line with international standards such as CE &
Adopted with Peltier precise temperature function technology
FAQs
1. What types of substances can be tested with the Melting Point Apparatus ?
The Melting Point Apparatus is suitable for testing a wide range of substances including oils, fats, pharmaceuticals, and organic compounds. It is commonly used in industries such as food, cosmetics, environmental science, and biochemistry. It handles both crystalline and semi-solid samples effectively using standard capillaries. Its versatility makes it a practical tool for laboratories with diverse testing needs.
2. Is the Melting Point Apparatus suitable for labs with high testing volume?
Melting Point Apparatus , while designed primarily for precision, supports moderate throughput with dual-sample capacity and fast temperature ramping. Its quick setup and efficient operation enable labs to process multiple samples in succession with minimal downtime. With internal storage for up to 400 results, it helps streamline workflow. This makes it well-suited for quality control and routine lab testing.
3. How does the Melting Point Apparatus help reduce human error during melting point determination?
The Melting Point Apparatus features a semi-automatic detection system that identifies melting points using visual and thermal signals, reducing manual observation. An integrated camera records the melting process for result verification. This enhances accuracy and supports training and audit documentation. The system ensures repeatability, essential for quality control and compliance.
4. How does the built-in camera in Melting Point Apparatus enhance the testing process?
Melting Point Apparatus features an integrated camera that captures real-time visuals of the melting process, eliminating the need for direct contact or a microscope. This visual data aids in confirming melting behavior and can be replayed for verification or training. It enhances user confidence and documentation, especially when evaluating borderline results. The video feature also minimizes the risk of missing subtle transitions during testing.
5. How long does it typically take to complete a single test in Melting Point Apparatus ?
The test duration in Melting Point Apparatus depends on the selected temperature gradient and the nature of the sample. With faster gradients, the apparatus can complete tests more quickly, though slower gradients are often preferred for higher accuracy. In most routine applications, a test can be completed within a few minutes. The device is designed to balance speed and precision, ensuring efficient workflow in busy labs.
6. What safety precautions should be followed while using the Melting Point Apparatus ?
Melting Point Apparatus is generally safe to operate, users should handle heated components with care to avoid burns. Samples must be properly sealed in capillaries to prevent spillage or contamination during heating. It’s important to avoid touching the sample chamber immediately after a test, as internal parts may remain hot for a short time. Following standard lab safety protocols and reviewing the user manual before use is highly recommended.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.