Melting Point Apparatus is microprocessor temperature control unit with fully automatic detection mode. Combines with high-precision temperature control technology and high definition video camera technology, which not only provides users with accurate, stable and reliable test results, but also brings users efficient and convenient test experience. High definition video can easily and clearly see the whole process of sample melting, automatic detection real-time map display, and convenient use to accurately measurement of samples melting point and melting distance.
This melting point apparatus is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Melting Point Apparatus is used in Chemical, pharmaceutical, food and drug manufacturing and research industry for quality and testing purpose. It is also used in cosmetics, dye and paint production and testing plants, laboratories.
Specifications
| Temperature range | Room temperature to 350 ℃ |
| Detection mode | Fully automatic (compatible with manual) |
| Processing capacity | 4 / batch |
| Judgment ability | Automatically judge color samples |
| Capillary size | Outer diameter 1.4 mm, Inner diameter 1.0 mm |
| Temperature resolution | 0.1 ℃ |
| Temperature control mode | precise temperature control |
| Heating rate | 0.1 ℃ / min or 20 ℃ / min |
| Accuracy | ± 0.3 ℃ (< 200 ℃) , ±0.5℃(>200℃) |
| Repeatability | Melting point repeatability ± 0.1 ℃ at 0.1 ℃ / min |
| Exploration mode | Yes |
| Magnification | ≥ 10 |
| Video function | Take photos |
| Video playback | With / with time watermark |
| HD camera | Observe the melting state of sample |
| Storage space | 16 g hard disk, ≥ 2G memory |
| Test method | Yes |
| Atlas preservation | 200 |
| Continuous shooting time | 50 minutes |
| Experimental scheme | 50 sets |
| Display mode | 8 inch high-definition color screen |
| Data interface | , network Wi-Fi interface, RS232 |
| Printer | Laser printer or thermal / needle type (compatible) |
| Power consumption | 120 W |
| Power supply | 220 V, 50 Hz |
| Dimension | 350*220*220 mm |
| Packing Dimension | 410*300*360 mm |
| Net Weight | 5 Kg |
| Gross Weight | 7.2 Kg |
Features
Designed with automatic integration to realize the function of one key measurement
High definition video instead of traditional visual microscope
It deal with four samples at a time
The data can be printed directly by printer
Design with precise temperature control and furnace body fully closed
Automatic recording of melting range, initial melting and final melting
Automatically upgraded U disk software without returning to the factory
Automatically judge color samples
Equipped with , network Wi-Fi interface, RS232 and tamper proof function
Designed with 8 inches high-definition color screen
FAQs
1. How does Melting Point Apparatus ensure consistency in results across operators?
The Melting Point Apparatus eliminates subjective judgment by using automatic image and color detection to determine the melting point. This reduces variability caused by human interpretation, especially when multiple users handle the instrument. The automated system ensures that results remain consistent even in high-throughput environments. It’s particularly valuable in multi-user labs or when results must stand up to audits.
2. What advantages does the touch-screen interface of Melting Point Apparatus provide for lab technicians?
Melting Point Apparatus features an 8-inch touch-screen interface that enhances usability by providing direct access to settings, real-time monitoring, and video playback. It eliminates the need for external computers or manual controls, streamlining the overall workflow. Operators can easily configure parameters, view stored data, and manage multiple test sessions through an intuitive interface. This design makes our apparatus more efficient and user-friendly for daily laboratory operations.
3. What is the advantage of having a programmable heating rate in Melting Point Apparatus ?
The programmable heating rate of Melting Point Apparatus allows users to adjust how quickly the temperature rises during a test. Slower rates improve accuracy by giving clearer melting transitions, while faster rates can be used for quick screening. This flexibility makes the apparatus suitable for both research and high-volume testing. Users can tailor the process based on the type and sensitivity of the sample.
4. Why is the inclusion of video playback important in routine testing with the Melting Point Apparatus ?
Melting Point Apparatus offers video playback that allows lab staff to review the melting process even after the test is complete. This feature is highly beneficial for validating results, training new personnel, or investigating unexpected outcomes. It provides a visual record that can be stored, shared, or included in quality assurance documentation. Playback ensures that every test can be revisited without the need to rerun the experiment, saving time and resources.
5. How does the enclosed furnace chamber in the Melting Point Apparatus improve performance?
The Melting Point Apparatus features an enclosed furnace chamber that ensures uniform heat distribution, minimizes heat loss, and protects samples from external temperature fluctuations. It also enhances safety by preventing direct contact with heated components. This stable testing environment improves result accuracy and extends the lifespan of internal sensors. The design is particularly beneficial in laboratories with fluctuating ambient conditions.