Introduction

Horizontal Electrophoresis System ( ) is designed with three platinum electrodes in which one stand for negative terminal and rest two are positive terminal. It is composed with a tank, swim clubs, latex tube and power cord that creates overall dimension of 296×266×122 mm. It is ideal for a wide range of samples such as plasmid preparation, reactions, restriction fragments, analyses etc. Cellulose acetate membrane () is a simple, rapid separation of biomolecules. ( ) Horizontal Electrophoresis System saves the sample, gives high specificity and strong resolution for analysis of the serum protein fraction. This dual tank electrophoresis works with Power Supply for to meet the requirements of standard acid electrophoresis, small and medium-sized vertical electrophoresis and transfer power supply. It is programmable and capable for storing 12 common procedures. The temperature control function is to ensure that the gel does not overheat (optional) and a better result must be obtained. This electrophoresis system is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Horizontal Electrophoresis System ( ) is a qualitative analysis method which is widely used in various fields such as immune electrophoresis and cellulose acetate membrane electrophoresis, purity detection of antigen and antibody, clinical examination, medical research and teaching experiment.

Specifications

Platinum Electrodes Three electrodes (one negative and two positive)
Number of Gel analysed 2
Immune For 1 to 20 slides
Comb Specifications
2×8 cm, can be used for 1 to 24
7×9 cm, can be used for 1 to 6
8×12 cm, can be used for 1 to 6
Composition Tank, swim clubs, latex tube and power cord
Dimension 296×266×122 mm
Weight 4 kg

Features

Horizontal Electrophoresis System ( ) Three electrodes (one negative and two positive)

Cellulose acetate membrane () is a simple, rapid separation of biomolecules

Immune; For 1 to 20 slides

Qualitative method for the analysis of the antigen composition

Saves the sample, provides high specificity and strong resolution

Overall composition are tank, swim clubs, latex tube and power cord

Compiled with Certification

Power Supply for Temperature control function to ensure that the gel does not overheat (optional)

Micro amps reading: user-friendly to observe electrophoresis at any time

Wide voltage and wide Hz for domestic and international use

Automatic recovery after power failure: record of the experiment at any time

Pause / Resume function to facilitate the continuous operation

Programmable and capable for storing 12 common procedures

FAQs

1. What are the key factors to consider when selecting this electrophoresis system for laboratory use?

When selecting this electrophoresis system, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this electrophoresis system be calibrated to ensure accurate results?

It is recommended to calibrate this electrophoresis system at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this electrophoresis system?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this electrophoresis system be used with different types of samples, and are there any compatibility considerations?

Yes, this electrophoresis system can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the electrophoresis system malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.