Introduction

Flammability Tester is a horizontal and vertical flame chamber with touch screen control panel, outdoor grade power coating technology, high texture and no discoloration. Equipped with explosion proof halogen lamp light source and exhaust system for proper functioning of flame chamber. Specific methane flow gas meter with adjustable flame angle in range of 0 to 45°. It is used in automobile manufacturing using flame cutting machine that centers sample on 2 mm cold plate. This test circuit is in standardization with 9772.3 and D635/3801/4804/4986 and is reliable, simple & easy to operate.

This test equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Suitable for research, production and quality inspection in automobile industries, combustible materials industries and electrical industries.

Specifications

Control system touch screen display
Burner height 50 mm
Flame angle 0 to 45° (adjustable)
Flame height 15 to 175 mm / min (adjustable)
Gas supply Methane
Gas flowmeter 20 to 200 ml / min (adjustable)
Gas press 50 to 200 mm
Burn time 0 to 99.99 s (adjustable)
Cabinet capacity 0.8 cubic meter with glass watch door
Interior lamp source Explosion proof halogen lamp 40 W
After flame time 0.1 s to 99.99 s (adjustable)
Sample vertical moving distance 450 mm
Sample horizontal moving distance 180 mm
Test precision 0.01 s
Internal dimension (W × D × H) 1200 × 600 × 1500 mm
External dimension (W × D × H) 1200 × 600 × 1120 mm
Packaging dimension (W × D × H) 1240 × 750 × 1600 mm
Power supply AC 220 V, 500 W
Net weight 125 kg
Gross weight 165 kg

Features

Outdoor grade power coating technology

Touch screen control system

Adjustable flame height and stable flame burner in accordance with 5025

U-pressure direct reading meter gauge

Specific methane gas flow meter

Features control components for safe and reliable operation

Standard 180 W exhaust fan

Anodized aluminum clamp

5 mm armoured glass viewing window

Chrome designed transmit mechanism with linear axis bearing drive

FAQs

1. What are the key factors to consider when selecting this test equipment for laboratory use?

When selecting this test equipment, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this test equipment be calibrated to ensure accurate results?

It is recommended to calibrate this test equipment at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this test equipment?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this test equipment be used with different types of samples, and are there any compatibility considerations?

Yes, this test equipment can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the test equipment malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.