Introduction
Benchtop Conductivity Meter with 7 inch display conducts up to 5 point calibration, automatically recognizes calibration standards. Comes with 03 reading mode: fast, medium, strict, custom to balance the work operations. The meter follows standards, lets the user collect data, track measurements, perform and check results, do analysis, and compare statistics..
This conductivity meter is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Used to test Conductivity, , Salinity, resistivity values of different type of liquid such as pure, hard/low conductivity water, distilled water. Also used in water purification labs, water testing and management plants, and water processing and packaging units for quality and research purpose.
Specifications
| Conductivity measurement range | 0.000 μS/cm to 3000mS/cm | ||||||
| Resistivity measurement range | 5.00 Ω·cm to 100.0 MΩ·cm | ||||||
| measurement range | 0.000 mg/L to 1000g/L | ||||||
| Salinity measurement range | 0.00 to 8.00 % | ||||||
| Temperature measurement range | -5.0 to 135.0 °C | ||||||
| Conductivity accuracy | ± 0.5 % FS | ||||||
| Resistivity accuracy | ± 0.5 % FS | ||||||
| accuracy | ± 0.5 % FS | ||||||
| Salinity accuracy | ± 0.1 % | ||||||
| Temperature accuracy | ± 0.1 °C | ||||||
| Automatic temperature compensation | Yes | ||||||
| Automatic calibration | Yes | ||||||
| Automatic range switching | Yes | ||||||
| Calibration function | Yes | ||||||
| Reading mode |
| ||||||
| Data interface | RS232, | ||||||
| Data storage | 1000 sets | ||||||
| Complied with specifications | Yes | ||||||
| Power supply | (Input: AC 100 to 240 V, 1.35 A) (Output: DC 24 V, 3A) | ||||||
| Dimension | 280 × 280 × 130 mm | ||||||
| Packaging Dimension | 350 × 400 × 400 mm | ||||||
| Net weight | 2.5 kg | ||||||
| Gross weight | 4kg |
Features
7 inch color touch screen
Automatic temperature compensation and calibration
Electrode correction function
5 point conductivity calibrations
Intelligent operating system
100 sets of measurement data
Different conductivity compensation methods (includes pure water)
Different salinity compensation methods (includes saline , brine water)
Supports , RS232 connection with PC, serial printer
Supports firmware upgrade, support U disk hot swap
FAQs
1. What types of liquids can be tested with It Benchtop Conductivity Meter ?
It Benchtop Conductivity Meter can test a wide range of liquids, including pure water, distilled water, hard/low conductivity water, and brine. It measures conductivity, , salinity, and resistivity, making it suitable for water purification labs, research, and water management plants. The meter's versatility allows accurate testing in diverse water quality applications. This makes it an essential tool for monitoring water treatment processes.
2. How does the Benchtop Conductivity Meter ensure accuracy in measurement?
The Benchtop Conductivity Meter provides high accuracy with ±0.5% FS for conductivity, resistivity, and , and ±0.1% for salinity. Automatic temperature compensation adjusts the readings to account for temperature variations. This ensures consistent, reliable results under different environmental conditions. These features make it ideal for precise water quality monitoring.
3. What are the different reading modes of Benchtop Conductivity Meter available, and when should each be used?
Benchtop Conductivity Meter offers three reading modes: fast, medium, and strict, as well as a custom mode for specific needs. "Fast" mode provides quick measurements, while "medium" and "strict" modes offer more precise results. Custom mode allows users to adjust settings based on specific operational requirements. This flexibility helps balance speed and accuracy depending on the application.
4. Can the Benchtop Conductivity Meter be connected to a computer for data analysis?
Yes, the Benchtop Conductivity Meter supports RS232 and connections for transferring data to a PC or serial printer. This enables efficient data storage and analysis on a computer. The device also supports firmware upgrades and U-disk hot swapping for added convenience. These features make it easy to integrate with external systems for detailed analysis.
5. How does the Benchtop Conductivity Meter comply with (Good Laboratory Practice) standards?
Benchtop Conductivity Meter complies with by providing automatic calibration, temperature compensation, and the ability to store up to 1000 measurement data sets. These features help users maintain traceable and accurate data. The meter allows users to review and analyze stored results, ensuring compliance with regulatory standards. This makes it a reliable tool for labs requiring precise data tracking.
6. What maintenance is required to keep the Benchtop Conductivity Meter in optimal working condition?
Benchtop Conductivity Meter requires regular cleaning of the conductivity electrode and temperature sensor and checking for wear or fouling. The electrodes should be checked and replace them if necessary. Users may ensure the power supply connections are secure and that the device's software is updated. Proper maintenance ensures the meter continues to perform accurately.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

